ISI-501-224B

500W True Sine Wave DC-AC Inverter with MPPT Solar Charger
ISI-501 series
File Name:ISI-501-SPEC 2018-01-15
Model Encoding
Bat. Voltage
AC Output Voltage
1:110VAC
2:230VAC
Output Wattage
Series Name
ISI ---501 112 A
Description
True sine wave output (THD<3%)
High surge power up to 1000W
High efficiency up to 88%
High frequency design
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage
/ Over temp. / Output short / Input polarity reverse / Overload
Built-in 500W MPPT solar charger, MPPT efficiency:98%(Typ.)
Built-in remote ON-OFF control
Built-in battery low relay contact
LED indicator for operation status and battery capacity
3 years warranty
Features Applications
A :TYPE A OUTLET
B :TYPE B OUTLET
C :TYPE C OUTLET
D :TYPE D OUTLET
E :TYPE E OUTLET
F :TYPE F OUTLET
U :TYPE U OUTLET
12:12VDC
AC Output
Receptacle
24:24VDC
Home appliance
Power tools
Portable equipment
Yacht
Vehicle
ISI-501 series integrates a DC/AC True Sine Wave Inverter and a MPPT charger. This series is a high
performance true sine wave DC/AC inverter which converts the DC electricity from a system consisting
of batteries and solar panels. ISI-501 is not only a high frequency designed inverter but also fully digitally
controlled by an advanced microprocessor. With true sine wave output, ISI-501 series can provide 500W
continuously, 550W for 60 seconds, and 1000W for 30 AC-cycles. This series incorporates a MPPT solar
charger, including the constant current and constant voltage charging
characteristics.
{
{
{
48:48VDC
File Name:ISI-501-SPEC 2018-01-15
500W True Sine Wave DC-AC Inverter with MPPT Solar Charger
ISI-501 series
ISI-501-112 ISI-501-124 ISI-501-148 ISI-501-212 ISI-501-224 ISI-501-248
200 / 220 / 230 / 240VAC selectable by setting button S.W
50 0.1Hz 50/60Hz selectable by setting button S.W±
15A30A 30A50A 50A 15A
48V24V 24V12V 12V 48V
42 ~ 60VDC21 ~ 30VDC 21 ~ 30VDC10.5 ~ 15VDC 10.5 ~ 15VDC 42 ~ 60VDC
87%87%85% 88%88%86%
MODEL
MAXIMUM OUTPUT POWER (Typ.)
WAVEFORM Note.1
OUTPUT
INVERTER
SECTION
FREQUENCY
AC REGULATION (Typ.)
FRONT PANEL INDICATOR
NO LOAD CURRENT DRAW (Typ.)
BAT. VOLTAGE
EFFICIENCY (Typ.)
Note.2
OFF MODE CURRENT DRAW (Typ.)
DC CURRENT (Typ.) Note.7
VOLTAGE RANGE Note.3,5
INPUT
OUTPUT
OVER TEMPERATURE
OUTPUT SHORT
100 / 110 / 115 / 120VAC selectable by setting button S.W
550W for 60 sec. / surge power 1000W for 30 cycles (112, 212 models : 495W for 60 sec. / surge power 900W for 30 cycles)
True sine wave (THD<3%)
60 0.1Hz 50/60Hz selectable by setting button S.W±
±
3%
Fault and operation status, Charger status, Battery capacity
1.25A 0.63A 0.32A 1.25A 0.63A 0.32A
1mA
Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
RATED POWER 450W 450W500W 500W
OVER LOAD (Typ.)
110% load for 60 sec.
Protection type : Shut down o/p voltage, re-power on to recover
OTHERS
PACKING
2.35Kg; 6pcs/15.1Kg/1.55CUFT
DIMENSION
205*158*67mm (L*W*H)
NOTE
1.THD is tested by rated power, linear load at 13V,26V,52V input voltage.
2.Efficiency is tested by 350W, linear load at 13V,26V,52V input voltage.
3.The tolerance of each voltage value by models
is : 112/212 0.5V ; 124/224 1V ; 148/248 2V.→± →± →±
4.Output derating capacity referenced by curve 1.
5.Input derating capacity referenced by curve 2.
6.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
7.DC current is tested by 500W, linear load at 12V,24V,48V input voltage.
8.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than ℃℃
2000m(6500ft).
AC VOLTAGE
Factory setting set at 110VAC
Factory setting set at 110VAC
Factory setting set at 230VAC
Factory setting set at 230VAC
PROTECTION
FUSE
CHARGER CURRENT (Typ.)
BATTERY TYPE
BAT. LOW ALARM Note.3
BAT. LOW SHUTDOWN Note.3
REVERSE POLARITY
MPPT CHARGER EFFICIENCY ( )
Typ.
40A*2 40A*1 20A*1 40A*2 40A*1 20A*2
30A 17A 8.5A 30A 17A 8.5A
Open & sealed Lead Acid
11.3V 22.5V 45V 11.3V 22.5V 45V
10.5V 21V 42V 10.5V 21V 42V
By internal fuse open
WORKING TEMP. Note.4
MPPT RANGE
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
-20 ~ +40 @ 100% load ; 60 @ 50% load℃℃
98%
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing
o
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
ENVIRONMENT
Compliance to FCC part 15 class B, EAC TP TC 020
Compliance to EAC TP TC 020
LVD
SAFETY STANDARDS
None
EAC TP TC 004 approved
Compliance to EN61000-4-2,3,8, EAC TP TC 020
Compliance to EN55032 class B, EAC TP TC 020
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25 / 70% RH
EN60950-1 (LVD)
EMC IMMUNITY
EMC EMISSION
GENERAL
MPPT / SOLAR
BATTERY SECTION
SECTION
SECTION
35 ~ 50V
25 ~ 50V
45 ~ 90V
35 ~ 90V
90 ~ 160V
70 ~ 160V
35 ~ 50V
25 ~ 50V
45 ~ 90V
35 ~ 90V
90 ~ 160V
70 ~ 160V
11A
500W
7A 4.5A 11A 7A 4.5A
OPEN CIRCUIT VOLTAGE RANGE
SOLAR INPUT CURRENT (Typ.)
SOLAR INPUT POWER (Typ.)
SAFETY
&
EMC
MTBF
57.8K hrs min. MIL-HDBK-217F (25 )
TYPE-A
Standard
Receptacle type
Country
Certificate
TYPE-B
Standard
TYPE-C
Optional
TYPE-D
Optional
TYPE-E
Optional
TYPE-F
Optional
USA
EUROPE
AUSTRALIA
U.K
JAPAN GFCI
AC Output Receptacles(Optional)
Optional
TYPE-U
UNIVERSAL
Non
SPECIFICATION
CURVE 1
AMBIENT TEMPERATURE ( )
-20 10 20 30 40 50 60 70
20
40
50
60
80
100
CURVE 2
BATTERY INPUT VOLTAGE (V)
10.5VDC
21VDC
42VDC
11.5VDC
23VDC
46VDC
15VDC
30VDC
60VDC
20
40
60
80
100
Derating Curve
LOAD (%)
LOAD (%)
(HORIZONTAL)
Charging Curve
Charge Current
Stage 1 Stage 2 Stage 3
Start
Charge Voltage
100%
10%
14.4V
28.8V
57.6V
Solar panel
MCU1
Bat. OVP
Bat. UVP
OTP1
MCU2
FILTER
OTP2
OLP
MPPT
REMOTE
ON/OFF
BATTERY LOW
DRY CONTACT
EMI
AUX.
BATTERY
12V/24V/48V
DC/DC DC/AC
OUTPUT VOLTAGE
LED
CHARGER
ALARM
FILTER
POWER
CONVERTER INVERTER
&
FREQUENCY
DISPLAY
FAN
AC OUTPUT
100~120VAC or
200~240VAC
50Hz or 60Hz
110VAC/60Hz
230VAC/50Hz
SETTING
(Selectable by setting
button)
MPPT CHARGER : 50KHz
DC/DC CONVERTER : 25KHz
DC/AC INVERTER : 20KHz
AUX. POWER : 100KHz
Stage 1 : Constant Current
Stage 3 : MPPT Charger OFF
*Constant current condition : Dependent on solar input current and MPPT
voltage of solar panel.
current and solar input power under 50W.
*MPPT charger OFF condition:
Charge current less than 10% rated charge
Stage 2 : Constant Voltage
File Name:ISI-501-SPEC 2018-01-15
Block Diagram
500W True Sine Wave DC-AC Inverter with MPPT Solar Charger
ISI-501 series

ISI-501-224B

Mfr. #:
Manufacturer:
Description:
Power Inverters 500W 24Vin 230VACout Inverter Euro
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: