http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load 12 Vin models: 30 mA typ.
24 Vin models: 17 mA typ.
48 Vin models: 10 mA typ.
Surge voltage 12 Vin models: 25 V max.
(100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise (input) EN 55022 Class A, FCC part 15, level A
Output Specifications
Voltage set accuracy ±1 %
Regulation – Input variation Vin min. to Vin max. 0.3 % max.
– Load variation 10 – 100 % 0.5 % max.
1.0 % max. for 3.3 VDC output models
Ripple and noise (20 MHz Bandwidth) 80 mVpk-pk max.
Temperature coefficient ±0.02 %/K
Output current limitation 110–160 % of Iout max., constand current
Short circuit protection indefinite (automatic recovery)
Minimum load 10 % of rated max. current (operation at lower
load condition is safe but output ripple will
increase)
Capacitive load 3.3 / 5 VDC models: 6‘800 µF max.
12 / 15 VDC models: 680 µF max.
±12 / ±15 VDC models: 270 µF max.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case temperature +100°C max.
– Storage –55°C to +125°C
Load derating – without heatsink 2.3 %/K above 60°C
– with heatsink 2.9 %/K above 70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >1 Mio h
Isolation voltage (60 sec.) – Input/Output 1‘500 VDC
Isolation capacitance – Input/Output 1‘200 pF typ.
Isolation resistance – Input/Output (500 VDC) >1’000 MOhm
Switching frequency (fixed) 330 kHz typ. (pulse width modulation PWM)
Remote On/Off: – On: 2.5 ... 100 VDC or open circuit.
– Off: –1 ... 1.0 VDC or short circuit pin 2 and pin 6
– Off standby input current: 5 mA max.
– Control common: referenced to negativ input
– Start-up delay: 15 ms
Safety approvals UL 60950-1, IEC/EN 60950-1 Compliance up
to 60 VDC input voltage (SELV limit)
– Certification documents www.tracopower.com/overview/ten20
DC/DC Converters
TEN 20 Series 20 Watt