Table 4. MAXIMUM RATINGS
Parameter Min Max Unit
Supply Voltage to Ground Potential -- 0 . 5 +7.0 V
DC Input Voltage (Except REF) -- 0 . 5 V
DD
+0.5 V
DC Input Voltage (REF) -- 0 . 5 7 V
Storage Temperature -- 6 5 +150 C
Maximum Soldering Temperature (10 sec) 260 C
Junction Temperature 150 C
Static Discharge Voltage (per MIL--STD--883, Method 3015) >2000 V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 5. OPERATING CONDITIONS
Parameter Description Min Max Unit
V
DD
Supply Voltage 3.0 3.6 V
T
A
Operating Temperature (Ambient Temperature) Industrial
Commercial
-- 4 0
0
85
70
C
C
L
Load Capacitance, below 100 MHz 30 pF
C
L
Load Capacitance, from 100 MHz to 133 MHz 15 pF
C
IN
Input Capacitance (Note 6) 7 pF
6. Applies to both REF Clock and FBK.
Table 6. ELECTRICAL CHARACTERISTICS V
CC
= 3.0 V to 3.6 V, GND = 0 V, T
A
=--40Cto+85C
Parameter
Description Test Conditions Min Max Unit
V
IL
Input LOW Voltage 0.8 V
V
IH
Input HIGH Voltage 2.0 V
I
IL
Input LOW Current V
IN
=0V 50.0
mA
I
IH
Input HIGH Current V
IN
=V
DD
100.0
mA
V
OL
Output LOW Voltage I
OL
= 8 mA (--1, --2, --3, --4)
I
OL
=12mA(--1H,--5H)
0.4 V
V
OH
Output HIGH Voltage I
OH
= --8 mA (--1, --2, --3, --4)
I
OH
= --12 mA (--1H, --5H)
2.4 V
I
DD
Supply Current (Note 7)
Unloaded outputs 100 MHz REF -- 2 , -- 3 , -- 4 49 mA
Select inputs at V
DD
or GND -- 1 H , -- 5 H 60 mA
Unloaded outputs, 66 MHz REF
(--1, --2, --3, --4)
34 mA
Unloaded outputs, 33 MHz REF
(--1, --2, --3, --4)
18 mA