8345-B03A-V3M0-DB1B1C-125A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Issue G
201
3
Current Trip curves and internal resistance () per pole
rating (A) F1 F2 K1, M1, T1, K2, M2, T2
0.05 276 152 452 376
0.1 58 37 100 94
1 0.58 0.35 0.95 0.90
2 0.145 0.096 0.26 0.20
3 0.065 0,048 0.10 0.10
5 0.025 < 0.02 0.042 0.040
10 < 0.02 < 0.02 < 0.02 < 0.02
15 < 0.02 < 0.02 < 0.02 < 0.02
20 < 0.02 < 0.02 < 0.02 < 0.02
25 < 0.02 < 0.02 < 0.02 < 0.02
30 < 0.02 < 0.02 < 0.02 < 0.02
40 < 0.01 < 0.01 < 0.01 < 0.01
50 < 0.01 < 0.01 < 0.01 < 0.01
60 < 0.01 < 0.01 < 0.01 < 0.01
80 < 0.01 < 0.01 < 0.01 < 0.01
100 < 0.01 < 0.01 < 0.01 < 0.01
125 < 0.01 < 0.01 < 0.01 < 0.01
Description
Typical applications
Approvals
Technical data
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching
characteristics ensures suitability for a wide range of applications.
Industry standard dimensions and panel mounting. Auxiliary contacts
optional. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934)S-type HM CBE.
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
8345
1 pole 2 pole
Voltage rating 3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V,
Current rating range 0.05...125 A single and multipole
150...180 A single pole, two poles
connected in parallel
higher ratings upon request
Auxiliary circuit AC 240 V/DC 28 V 6 A
DC 65 V 1 A; DC 80 V 0.5 A
Typical life 10,000 operations at 1 x I
N
Ambient temperature -40 °C...+85 °C (-40 °...+185 °F)
Insulation co-ordination
(IEC 60664) 2.5 kV/2
reinforced insulation in operating area
Dielectric strength test voltage
operating area AC 3000 V
pole to pole AC 1500 V
main to auxiliary circuit AC 1500 V
switching to trip circuit AC 1500 V
Insulation resistance > 100 M (DC 500 V)
Degree of protection operating area IP40
(IEC 60529) terminal area IP00
Vibration with toggle down:
10 g (57-2000 Hz) ±0,76mm (10-57Hz)
at 0.9 I
N
directions 1,2,3,4,5: 10 g at 1 x I
N
with curves F1, F2:
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ±0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock directions 1,2,3,4,5:
100 g (11 ms) at 1 x I
N
,
direction 6:
100 g (11 ms) at 0.8 x I
N
,
with curves F1, F2:
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5% salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
Mass approx. 90 - 120 g per pole
depending on version
VDE (EN 60934)
UL 489
UL 1077
Standard current ratings and typical internal resistance values
WE
N
Interrupting capacity
to EN 60934, UL 489 and UL 1077
IEC 60934 – test series E
voltage
number of poles I
N
max. (A) I
cn
DC 80 V 1 0.05...125 10,000
DC 80 V 2 0.05...125 10,000
AC 240 V 1 0.05...125 5,000
AC 240/415 V 3 (4) 0.05...125 5,000
UL 489 – test sequence Z
voltage
number of poles I
N
max. (A) I
cn
DC 80 V 1 0.05...125 10,000
DC 80 V 2 0.05...125 10,000
AC 120 V 1 0.05...80 5,000
AC 240 V 1 0.05...20 5,000
AC 120/240 V 1 (2) 0.05...80 5,000
UL 1077
voltage number of poles I
N
max. (A) I
cn
DC 80 V 1-6 0.05...125 10,000
AC 277/480 V 1-6 0.05...125 5,000
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Issue G202
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
3
Type number
X8345
Module
S auxiliary contact module
Auxiliary contacts
01 in all poles
02 in pole 1 only
03 in poles 1 + 3 only
04 in pole 2 only
Auxiliary contact version
H auxiliary contacts standard
(asymmetrical terminals not for UL 489)
K auxiliary contacts (symmetrical terminals)
Auxiliary contact function
W1 1 changeover
Terminal design
02 microswitch with blade terminals
DIN 46244-A2,8-0,5
M mounted to base unit
X8345 - S 01 H W1 02 M ordering example
Ordering information for auxiliary contact module
Ordering information
Type No.
8345
Mounting
B flange mounting, with rectangular aperture with mounting nut 6-32 UNC
C flange mounting, with rectangular aperture with mounting nut M3
E flange mounting, with round aperture with mounting nut 6-32 UNC
F flange mounting, with round aperture with mounting nut M3
Configuration
0 without barrier
1 with small barrier
2 with large barrier (required for UL 489 multipole)
Number of poles
0 single pole unprotected
1 single pole protected
2 two pole protected
3 three pole protected
4 four pole protected
P single pole protected, two poles connected in prallel
Actuator configuration
A all poles with standard toggle
B reduced number of standard toggles
Z without actuator
Terminal design
K screw terminals M4 35 A
L screw terminals M5 50 A
M solder terminals 75 A
P blade terminals 35 A
R round connectors 6 mm
S stud terminals M5 60 A
T stud terminals 10-32 UNF-3A 60 A
U stud terminals M6
V stud terminals 1/4-20UNC-3A 125 A
Terminal hardware
0 without
3 with washer and nut
6 Phillips screws
Characteristic curve
F1 instantaneous trip DC 1.01-1.5 x I
N
F2 instantaneous trip AC 1.01-1.5 x I
N
K1 short delay DC
K2 short delay AC
M0 medium delay AC/DC
M1 medium delay DC
M2 medium delay AC
Q0 switch only
T1 long delay DC
T2 long delay AC
Illumination
- without
Version
D standard
Colour configuration
B1 black front plate, black actuator,
(black actuator base)
B2 black front plate, black actuator,
(white actuator base)
Marking
front plate actuator base
A1 without without
A2 I
N
without
A3 I
N
without
characteristic curve
A4 I
N,
without
characteristic curve,
wiring diagram on side
B1 without ON-OFF
B2 I
N
ON-OFF
B3 I
N
ON-OFF
characteristic curve
B4 I
N
, ON-OFF
characteristic curve,
wiring diagram on side
Rated voltage
B AC or 80 V DC
8345 - C 0 1 A - U 3 M1 - . D B1 A1 B - 60 A - ...
8345 - C 0 1 A - U 3 M1 - . D B1 A1 B - ...
Current ratings
0.1...125 A
150 - 180 A
single pole protected,
two poles connected in parallel
Approvals (optional)
V UL 489
8345 - C 0 1 A - U 3 M1 - . D B1 A1 B - 60 A - . ordering example
Remote trip coil available to special order!
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Issue G
203
3
reduced number of toggles per unit
1 toggle per pole
A
B
Z
without toggles
B
Actuator configuration
ø14.5
LOAD LINE
number of poles 1 to 4
pole
Mounting version E/F
Flange mounting round aperture
mounting thread M3 or 6-32
mounting depth 4.2 mm/.165 in.
Cut-out dimensions:
Cut-out dimensions:
48
63.5
28.6
pole
52.4
36.8
11
19.2
ø4
28.6
47.6
9.6
19
12 34
Mounting version B/C
Flange mounting rectangular aperture
number of poles 1 to 4
mounting thread M3 or 6-32
mounting depth 4.2 mm/.165 in.
48
63.5
28.6
19
12 34
19
3.5
±
0.1
(M3)
4
+0.1
-0.15
(6-32UNC)
15.45
1 pole 4 pole
.571
.138
±
.004
(M3)
.157
+.004
-.006
(6-32UNC)
.608
.748
.748
2.50
.748
1.89
1.13
1 pole
multipole
2.62
1.87
.378
1.13
.157
1.45
2.06
.433
.756
2.50
1.89
1.13
38
57
66.6
76.2
3.00
LOAD LINE
44.75
1.76
ø14.5
.571
1.50
2.24
ON
OFF
68
2.25
68
2.25
ON
OFF
Dimensions Installation drawing
mounting
area
operating area
(reinforced insulation)
terminal
area
.039
1.14
1.18
.315
.079
.079
1
8
30
29
2
2
LOAD
LINE
This is a metric design and millimeter dimensions take precedence (
mm
)
inch

8345-B03A-V3M0-DB1B1C-125A