Software Protected Program Waveform
(1)(2)(3)
Notes: 1. A7 through A15 must specify the sector address during each high to low transition of WE (or CE) after the software code
has been entered.
2. OE
must be high when WE and CE are both low.
3. All words that are not loaded within the sector being programmed will be indeterminate.
Programming Algorithm
(1)
Program Cycle Characteristics
Symbol Parameter Min Max Units
t
WC
Write Cycle Time 20 ms
t
AS
Address Set-up Time 0 ns
t
AH
Address Hold Time 100 ns
t
DS
Data Set-up Time 100 ns
t
DH
Data Hold Time 0 ns
t
WP
Write Pulse Width 200 ns
t
WLC
Word Load Cycle Time 150 µs
t
WPH
Write Pulse Width High 200 ns
LOAD DATA AAAA
TO
ADDRESS 5555
LOAD DATA 5555
TO
ADDRESS 2AAA
LOAD DATA A0A0
TO
ADDRESS 5555
LOAD DATA
TO
SECTOR (128 BYTES)
(3)
WRITES ENABLED
ENTER DATA
PROTECT STATE
(2)
Notes for software program code:
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Data Protect state will be re-activated at end of program
cycle.
3. 128 words of data MUST BE loaded.
AT29LV1024
8
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristics.
Data Polling Waveforms
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristics.
Toggle Bit Waveforms
(1)(2)(3)
Notes: 1. Toggling either OE or CE or both OE and CE will operate toggle bit.
2. Beginning and ending state of I/O6 and I/O14 may vary.
3. Any address location may be used but the address should not vary.
Data Polling Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 0 ns
t
OEH
OE Hold Time 0 ns
t
OE
OE to Output Delay
(2)
ns
t
WR
Write Recovery Time 0 ns
Toggle Bit Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 10 ns
t
OEH
OE Hold Time 10 ns
t
OE
OE to Output Delay
(2)
ns
t
OEHP
OE High Pulse 150 ns
t
WR
Write Recovery Time 0 ns
I/O6 OR
I/O14
WE
CE
OE
AT29LV1024
9
Software Product Identification Entry
(1)
Notes for software product identification:
1. Data Format: I/O15 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. A1 - A15 = V
IL
.
Manufacturer Code is read for A0 = V
IL
;
Device Code is read for A0 = V
IH
.
3. The device does not remain in identification mode if
powered down.
4. The device returns to standard operation mode.
5. Manufacturer Code is 1F. The Device Code is 26.
Software Product Identification Exit
(1)
LOAD DATA AAAA
TO
ADDRESS 5555
LOAD DATA 5555
TO
ADDRESS 2AAA
LOAD DATA 9090
TO
ADDRESS 5555
PAUSE 20 mS ENTER PRODUCT
IDENTIFICATION
MODE
(2)(3)(5)
LOAD DATA AAAA
TO
ADDRESS 5555
LOAD DATA 5555
TO
ADDRESS 2AAA
LOAD DATA F0F0
TO
ADDRESS 5555
PAUSE 20 mS EXIT PRODUCT
IDENTIFICATION
MODE
(4)

AT29LV1024-15TC

Mfr. #:
Manufacturer:
Description:
IC FLASH 1M PARALLEL 48TSOP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union