cui.com
date 08/13/2013 │ page 2 of 5CUI Inc │ SERIES: VF-S250-XXA │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90-132/180-264 auto selectable 90/180 132/264 Vac
frequency 47 63 Hz
current
at 110~120 Vac, cold start
at 200~240 Vac, cold start
6
3
A
A
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
35
70
A
A
power factor compliant to EN 61000-3-2 class A
remote on/off designated as RMSW on the CN1, requires a low signal to inhibit output, hiccup mode
OUTPUT
parameter conditions/description min typ max units
line regulation low line to high line ±1 %
load regulation all other outputs ±1 %
temperature coeffi cient 0.25 mV/°C
transient response
output voltage returns to within 1% in less than 2.5 ms for a 50% load change
peak transient does not exceed 5%.
start-up time at 120 Vac 1s
rise time 0.2 20 ms
hold-up time at 120 Vac and 80% of rated maximim load 20 ms
adjustability ±5 %
power good
designated as PG on the CN1, signal goes high 100~500 ms after the output
reaches regulation, signal goes low at least 1 ms before loss of regulation
fan drive 12 Vdc / 300 mA for external fan
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection AC input needs to be reset to restart the power supply 130 %
over current protection automatically recovers 110 140 %
short circuit protection short circuit can be continuous, recovers automatically upon removal of short
over temperature protection auto recovery 85 °C
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
for 3 seconds at 10 mA max
primary to secondary:
primary to transformer core:
primary to earth chassis:
3,000
1,500
1,500
Vac
Vac
Vac
safety approvals UL 60950-1, CSA C22.2 No. 60950-1, TUV EN 60950-1 and CB
EMI/EMC
CISPR 22/EN 55022 class B, EN 61000-3-2, 3,
EN 61000-4-2, 3, 4, 5, 6, 8, 11, EN 55024 CE marked (LVD)
leakage current
at 240 Vac, (optional for 500 A at 240 Vac,
300 A at 120 Vac)
1.5 mA
MTBF according to MIL-HDBK-217 at 30ºC 100,000 hrs
RoHS compliant yes
For more information, please visit the product page.