SERIES: VF-S250-XXA DESCRIPTION: AC-DC POWER SUPPLY
MODEL
output
voltage
output
current
output
1
power
ripple and
noise
2,3
ef ciency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VF-S250-05A 5 40 200 50 75%
VF-S250-09A 9 25 225 90 83%
VF-S250-12A 12 20.83 250 120 80%
VF-S250-15A 15 16.67 250 150 83%
VF-S250-18A 18 13.89 250 180 83%
VF-S250-24A 24 10.42 250 240 83%
VF-S250-28A 28 8.93 250 280 83%
VF-S250-36A 36 6.93 250 360 83%
VF-S250-48A 48 5.21 250 480 83%
VF-S250-54A 54 4.63 250 540 83%
PART NUMBER KEY
VF - S250 - XX A - X X
Base Number
Output Voltage
FEATURES
• up to 250 W continuous power
• 600 W peak power within 500 s duty duration
• passive power factor correction
• power good signal
• remote on/off control
• 3000 Vac isolation voltage
• over load, over voltage, over temperature, and short circuit protections
• UL, cUL, and TUV 60950-1 safety approvals
• efficiency up to 85%
RoHS
i
on
s
Notes: 1. Maximum power must not exceed 135 W with convection cooling or 250 W for forced air. 5 and 9 V models maximum current listed.
2. 1% minimum load is required to maintain the ripple and regulation.
3. Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 F ceramic capacitor and a 22 F electrolytic capacitor in parallel.
Input/Output connector:
“blank” = Terminal block input / Terminal block output
1 = Molex input / Molex output
2 = Molex input / Terminal block output
3 = Terminal block input / Molex output
Low leakage option:
“blank” = standard speci cation
L = low leakage (contact factory)
For more information, please visit the product page.
cui.com
date 08/13/2013 page 2 of 5CUI Inc SERIES: VF-S250-XXA DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90-132/180-264 auto selectable 90/180 132/264 Vac
frequency 47 63 Hz
current
at 110~120 Vac, cold start
at 200~240 Vac, cold start
6
3
A
A
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
35
70
A
A
power factor compliant to EN 61000-3-2 class A
remote on/off designated as RMSW on the CN1, requires a low signal to inhibit output, hiccup mode
OUTPUT
parameter conditions/description min typ max units
line regulation low line to high line ±1 %
load regulation all other outputs ±1 %
temperature coef cient 0.25 mV/°C
transient response
output voltage returns to within 1% in less than 2.5 ms for a 50% load change
peak transient does not exceed 5%.
start-up time at 120 Vac 1s
rise time 0.2 20 ms
hold-up time at 120 Vac and 80% of rated maximim load 20 ms
adjustability ±5 %
power good
designated as PG on the CN1, signal goes high 100~500 ms after the output
reaches regulation, signal goes low at least 1 ms before loss of regulation
fan drive 12 Vdc / 300 mA for external fan
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection AC input needs to be reset to restart the power supply 130 %
over current protection automatically recovers 110 140 %
short circuit protection short circuit can be continuous, recovers automatically upon removal of short
over temperature protection auto recovery 85 °C
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
for 3 seconds at 10 mA max
primary to secondary:
primary to transformer core:
primary to earth chassis:
3,000
1,500
1,500
Vac
Vac
Vac
safety approvals UL 60950-1, CSA C22.2 No. 60950-1, TUV EN 60950-1 and CB
EMI/EMC
CISPR 22/EN 55022 class B, EN 61000-3-2, 3,
EN 61000-4-2, 3, 4, 5, 6, 8, 11, EN 55024 CE marked (LVD)
leakage current
at 240 Vac, (optional for 500 A at 240 Vac,
300 A at 120 Vac)
1.5 mA
MTBF according to MIL-HDBK-217 at 30ºC 100,000 hrs
RoHS compliant yes
For more information, please visit the product page.
cui.com
date 08/13/2013 page 3 of 5CUI Inc SERIES: VF-S250-XXA DESCRIPTION: AC-DC POWER SUPPLY
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 070°C
storage temperature -20 85 °C
operating humidity non-condensing 5% 90% %
storage humidity non-condensing 5% 95% %
vibration acceleration ±7.35 M/(SxS), on X, Y and Z Axis 5 50 Hz
100
80
60
50
40
20
Ambient Temperature (°C)
Load (%)
010203040506070
DERATING CURVE
output power vs. ambient temperature