Data Sheet
April 2008
LC/LW005-Series Power Modules:
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 5 W
The LC/LW005-Series Power Modules use advanced, surface-
mount technology and deliver high-quality, compact, dc-dc
conversion at an economical price.
Applications
n Computer equipment
n Communications equipment
n Distributed power architectures
Options
n Positive remote on-off logic
n Short pins: 2.8 mm ± 0.25 mm
(0.110 in. ± 0.010 in.)
n Synchronization
n Tight output voltage tolerance
Features
n Low profile: 10.2 mm x 25.4 mm x 32 mm
(0.400 in. x 1 in. x 1.26 in.) with standoffs
(9.78 mm (0.385 in.) with standoffs recessed)
n Wide input voltage range: 18 Vdc to 36 Vdc or
36 Vdc to 75 Vdc
n Input-to-output isolation up to 1500 V
n Operating case temperature range: –40 °C to
+105 °C
n Overcurrent protection, unlimited duration
n Output overvoltage protection
n Undervoltage lockout
n UL* 1950 Recognized, CSA
C22.2 No. 950-95
Certified, VDE
0805 (EN60950, IEC950) Licensed
n CE mark meets 73/23/EEC and 93/68/EEC
directives
n Within FCC Class A radiated limits
* UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Associa-
tion.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§ This product is intended for integration into end-use equipment.
All the required procedures for CE marking of end-use equip-
ment should be followed. (The CE mark is placed on selected
products.)
Description
The LC/LW005-Series Power Modules are low-profile, dc-dc converters that operate over an input voltage
range of 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc and provide a precisely regulated output. The output is isolated
from the input, allowing versatile polarity configurations and grounding connections. The modules have a maxi-
mum power rating of 5 W and efficiencies greater than 75%. Built-in filtering for both input and output minimizes
the need for external filtering.
2 Lineage Power
Data Sheet
April 2008
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 5 W
LC/LW005-Series Power Modules:
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
Parameter Device Symbol Min Typ Max Unit
Input Voltage:
Continuous
Transient (100 ms)
LC
LW
LW
V
I
VI
VI, trans
0
0
0
50
80
100
Vdc
Vdc
V
Operating Case Temperature All T
C –40 105 °C
Operating Ambient Temperature in
Natural Convection (See Thermal Con-
siderations section.)
All T
A –40 85 °C
Storage Temperature All T
stg –55 125 °C
I/O Isolation Voltage (1 minute) All 1500 Vdc
Parameter Device Symbol Min Typ Max Unit
Operating Input Voltage LC
LW
V
I
VI
18
36
24
48
36
75
Vdc
Vdc
Maximum Input Current
(V
I = 0 to VI, max; IO = IO, max; see Figures
1 and 2.)
LC
LW
I
I, max
II, max
0.6
0.3
A
A
Inrush Transient All
I
2
t
——0.2
A
2
s
Input Reflected-ripple Current
(5 Hz to 20 MHz; 12 µH source
impedance; T
C = 25 °C; see Figure 16.)
All I
I —5—mAp-p
Input Ripple Rejection
(100 Hz—120 Hz)
All 45 dB
Lineage Power 3
Data Sheet
April 2008
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 5 W
LC/LW005-Series Power Modules:
Electrical Specifications (continued)
Table 2. Output Specifications
Parameter
Device Code
or Suffix
Symbol Min Typ Max Unit
Output Voltage Set Point
(V
I = VI, nom; IO = IO, max; TC = 25 °C)
F
A
B
C
V
O, set
VO, set
VO, set
VO, set
3.17
4.85
11.52
14.40
3.43
5.20
12.48
15.60
Vdc
Vdc
Vdc
Vdc
Output Voltage
(Over all line, load, and temperature
conditions until end of life; see
Figure 18.)
F
A
B
C
V
O
VO
VO
VO
3.13
4.80
11.40
14.25
3.47
5.25
12.60
15.75
Vdc
Vdc
Vdc
Vdc
Output Regulation:
Line (V
I = VI, min to VI, max)
Load (I
O = IO, min to IO, max; see
Figure 3.)
Temperature
(T
C = –40 °C to +85 °C)
A, F
B, C
A, F
B, C
A, F
B, C
2
0.03
2
0.1
25
0.5
5
0.1
10
0.2
100
2.0
mV
%V
O
mV
%V
O
mV
%V
O
Output Ripple and Noise Voltage:
With an External 0.1 µF Ceramic
Output Capacitor (See Figure 17.):
RMS
Peak-to-peak (5 Hz to 20 MHz)
With an External 3.3 µF Ceramic
Output Capacitor:
RMS
Peak-to-peak (5 Hz to 20 MHz)
All
All
A, F
A, F
35
150
30
100
mVrms
mVp-p
mVrms
mVp-p
External Load Capacitance A, F
B, C
0
0
470
100
µF
µF
Output Current
(At I
O < IO, min, the modules may exceed
output ripple specifications, but opera-
tion is guaranteed.)
F
A
B
C
I
O
IO
IO
IO
0.12
0.1
0.08
0.06
1.21
1.0
0.42
0.33
A
A
A
A
Output Current-limit Inception
(V
O = 90% VO, set; see Figure 4.)
F
A
B, C
I
O
IO
IO
1.7
1.4
0.6
3.0
2
0.9
A
A
A
Output Short-circuit Current
(V
O = 0.25 V)
F
A
B, C
I
O
IO
IO
2.4
2.2
1.0
4.5
4.0
2.5
A
A
A
Efficiency
(V
I = VI, nom; IO = IO, max; TC = 25 °C;
see Figures 6 through 8.)
LC005F
LC005A
LC005B, C
LW005F
LW005A, B, C
η
η
η
η
η
69
73
71
71
75
72
76
74
74
78
%
%
%
%
%
Switching Frequency All 300 kHz

LC005A

Mfr. #:
Manufacturer:
ABB Embedded Power
Description:
Isolated DC/DC Converters 5V 1A 5W 5-Pin
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet