Reliability data
Test Standard Test conditions ∆R
25
/R
25
Electrical endurance,
cycling
IEC 60738-1 Room temperature, I
Smax
; V
max
Number of cycles: 100
< 25%
< 10%
1)
Electrical endurance,
constant
IEC 60738-1 Storage at V
max
and T
op,max
(@ V
max
)
Test duration: 1000 h
< 25%
< 20%
1)
Damp heat IEC 60738-1 Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
< 10%
Rapid change
of temperature
IEC 60738-1 T
1
= T
op,min
(0 V), T
2
= T
op,max
(0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, test Na
< 10%
Vibration IEC 60738-1 Frequency range: 10 - 55 - 10 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, test Fc
< 5%
< 10%
1)
Shock IEC 60738-1 Pulse shape: half-sine
Acceleration: 400 m/s
2
Pulse duration: 6 ms; 6 x 5000 pulses
Test according to IEC 60068-2-27, test Ea
< 5%
< 10%
1)
Climatic sequence IEC 60738-1 Dry heat: T = T
op,max
(0 V)
Test duration: 16 h
Damp heat first cycle
Cold: T = T
op,min
(0 V)
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
< 10%
Bending test IEC 60738-1 Components reflow-soldered to test board
Maximum bending: 2 mm
Test according to IEC 60068-2-21, test Ue
< 10%
Adhesive strength on
PCB
Shearing of the component soldered on
PCB by a force of 5 N normal to
components longitudinal axis
No visible
damage
1) For type A407, B59407A0115A062
Overcurrent protection
SMDs, EIA sizes 0402, 0603 and 1210, 24 V up to 230 V
Page 5 of 16Please read Cautions and warnings and
Important notes at the end of this document.