CONREVSMA012

NOTES: (UNLESS OTHERWISE SPECIFIED)
1. ALL DIMENSIONS ARE IN INCHES [mm].
2. DIMENSIONS APPLY AFTER FINISHING.
3. MANUFACTURE TO BE COMPLIANT WITH EU RoHS DIRECTIVE.
4. SAFETY BREAK ALL SHARP CORNERS AND EDGES .02 MAXIMUM.
SHEET 1 OF 1
LDCFDLT_A
SCALE: 2:1
TITLE:
SIZE
DWG. NO.
REV
DO NOT SCALE DRAWING
ANGLES:
1
TOLERANCES:
.020 [0.50]-.200 [5.00]=
.008 [0.20]
.200 [5.00]-1.200 [30.00]=
.016 [0.40]
1.20 [30.0]-4.75 [120.0]=
.024 [0.60]
4.75 [120.0]-12.40 [315.0]=
.040 [1.0]
DRAWN:
ENGR:
DT:
DT:
MATERIAL:
FINISH:
PROJECTION:
:
THIS DRAWING CONTAINS PROPRIETARY INFORMATION
THAT IS THE SOLE PROPERTY OF LINX TECHNOLOGIES, AND SHALL BE
TREATED AS SUCH. NO DISCLOSURE OR REPRODUCTION OF THIS
DOCUMENT IS PERMITTED, IN WHOLE OR IN PART, WITHOUT THE
EXPRESS WRITTEN PERMISSION OF LINX TECHNOLOGIES OR ITS
DESIGNATED AGENTS.
159 ORT LANE
MERLIN, OR 97532
2-JUL-12
CONREVSMA012
D
2-JUL-12
B.MURPHY
0.374
[9.50]
Ø0.154
[3.90]
CRIMP RING
Ø0.197
[5.00]
0.787
[20.00]
HEAT SHRINK
1/4-36UNS-2B
THREADS
S.HOGAN
24-MAY-16
RECOMMENDED CABLE STRIPPING DIMENSIONS
Descripon Material Finish
Body
Socket
Insulaon
Nickel
N/A
Gold
PTFE
Brass
Be Cu
Washer Ph Bronze Nickel
Gasket N/ASi Rubber
Crimp Ring NickelBrass
Insulator N/APTFE
Cover NickelBrass
PolyolefinHeat Shrink Black
0.197
[5.00]
0.118
[3.00]
0.098
[2.50]
RG-174 Cable
BRAIDED SHIELD
0.197
[5.00]
0.287
[7.30]
Ø0.106
[2.70]
0.650
[16.50]
0.331
[8.40]
0.287
[7.30]
Ø0.260
[6.60]
SIDE VIEW
INSULATORCOVER
Ø0.185
[4.70]
Ø0.146
[3.70]
0.055
[1.40]
0.051
[1.30]
REVISIONS
REV
DESCRIPTION
DATE
APPV
B
Add Heat Shrink to Drawing
28-JUL-09
CJ
C
SAH
Updated dimensions, instructions; Added new title block
BARREL
RP-SMA MALE RIGHT ANGLE
CABLE END CRIMP FOR RG174 CABLE
CONREVSMA012 ASSEMBLY INSTRUCTIONS
1. Strip the cable to the recommended dimensions.
2. Slip heat shrink and crimp ring onto stripped cable.
2. Slide the cable into the body until the center conductor is
centered in the fork.
3. Push the braided shield over the barrel.
4. Solder the center conductor into the center of the fork.
5. Slide the crimp ring over the shield and crimp with a 0.128”
hex crimp tool (or one labeled for use with RG-174 cable).
6. Trim off any excess shield wire sticking out from the ring.
7. Slip the heat shrink over the crimp ring until it is against the
body and shrink.
8. Insert insulator into body.
9. Push the cover into the opening.
24-MAY-16
D
SAH
Updated cable stripping dimensions

CONREVSMA012