2) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Useful life
depending on ambient temperature T
A
under ripple current operating conditions at V
op
2)
V
R
= 25 V: V
op
20 V V
R
= 40 V: V
op
35 V
V
R
= 63 V: V
op
55 V V
R
= 75 V: V
op
65 V
Useful life
depending on case temperature T
C
under ripple current operating conditions at V
op
2)
V
R
= 25 V: V
op
20 V V
R
= 40 V: V
op
35 V
V
R
= 63 V: V
op
55 V V
R
= 75 V: V
op
65 V
B41695, B41795
Compact up to 150 °C
Page 10 of 17Please read Cautions and warnings and
Important notes at the end of this document.
Frequency factor of permissible ripple
current I
AC
versus frequency f
Frequency characteristics of ESR
Typical behavior
Equivalent series resistance ESR
versus frequency f
Typical behavior for 2200 µF/40 V
Impedance Z
versus frequency f
Typical behavior for 2200 µF/40 V
B41695, B41795
Compact up to 150 °C
Page 11 of 17Please read Cautions and warnings and
Important notes at the end of this document.
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling aluminum electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
B41695, B41795
Compact up to 150 °C
Page 12 of 17Please read Cautions and warnings and
Important notes at the end of this document.

B41695A5158Q7

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Aluminum Electrolytic Capacitors - Axial Leaded AL-ELKO AXIAL LEADED 1500UF 25V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: