Table 6. 100EL SERIES NECL DC CHARACTERISTICS V
CC
= 0.0 V; V
EE
= −5.0 V (Note 8)
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
I
EE
Power Supply Current 14 17 14 17 16 20 mA
V
OH
Output HIGH Voltage (Note 9) −1085 −1005 −880 −1025 −955 −880 −1025 −955 −880 mV
V
OL
Output LOW Voltage (Note 9) −1830 −1695 −1555 −1810 −1705 −1620 −1810 −1705 −1620 mV
V
IH
Input HIGH Voltage −1165 −880 −1165 −880 −1165 −880 mV
V
IL
Input LOW Voltage −1810 −1475 −1810 −1475 −1810 −1475 mV
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current 0.5 0.5 0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
8. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.8 V / −0.5 V.
9. Outputs are terminated through a 50 W resistor to V
CC
− 2 volts.
Table 7. AC CHARACTERISTICS V
CC
= 5.0 V; V
EE
= 0.0 V or V
CC
= 0.0 V; V
EE
= −5.0 V (Note 9)
Symbol Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
f
max
Maximum Toggle Frequency TBD TBD TBD GHz
t
PLH
t
PHL
Propagation Delay to
Output
120 280 500 180 290 450 210 320 480 ps
t
JITTER
Cycle−to−Cycle Jitter TBD TBD TBD ps
t
r
t
f
Output Rise/Fall Times Q
(20% − 80%)
150 350 550 150 350 550 150 350 550 ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
10.10 Series: V
EE
can vary +0.06 V / −0.5 V.
100 Series: V
EE
can vary +0.8 V / −0.5 V.
Figure 2. Typical Termination for Output Driver and Device Evaluation
(See Application Note AND8020/D − Termination of ECL Logic Devices.)
Driver
Device
Receiver
Device
QD
Q D
Z
o
= 50 W
Z
o
= 50 W
50 W 50 W
V
TT
V
TT
= V
CC
− 3.0 V