SP
–3–
ASCTB208E 201606-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Characteristics Item Specifications
Contact
Initial contact pressure 2 Form C: Approx. 0.392 N (40 g 1.41 oz), 4 Form C: Approx. 0.196 N (20 g 0.71 oz)
Arrangement 2 Form C, 4 Form C
Contact resistance (Initial) Max. 30 mΩ (By voltage drop 6 V DC 1A)
Contact material Stationary contact: Au flashed AgSnO2 type, Movable contact: AgSnO2 type
Rating
Nominal switching capacity (resistive load) 2 Form C: 15 A 250 V AC, 4 Form C: 10 A 250 V AC
Max. switching power (resistive load) 2 Form C: 3,750 VA, 300 W, 4 Form C: 2,500 VA, 300 W
Max. switching voltage 2 Form C, 4 Form C: 250 V AC, 30 V DC (48V DC: Max. 2A)
Max. switching current 2 Form C: 15 A (AC) 10 A (DC), 4 Form C: 10 A
Nominal operating power 300mW (Single side stable, 2 coil latching)
Min. switching capacity (reference value)*
1
100 mA 5V DC
Electrical
characteristics
Insulation resistance (Initial)
(25°C, 50% relative humidity)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,500 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 3,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact sets 3,000 Vrms for 1 min. (Detection current: 10 mA)
Operate time [Set time] (at 20°C 68°F) (Initial)
Max. 30 ms [Max. 30 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F) (Initial)
Max. 20 ms [Max. 30 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 392 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 3 mm
Expected life
Mechanical Min. 5×10
7
(at 180 times/min.)
Electrical (resistive load)
2 Form C:
Min. 10
5
(15 A 250 V AC [at 20 times/min.]), Min. 10
5
(10 A 30 V DC [at 20 times/min.])
4 Form C:
Min. 10
5
(15 A 250 V AC [at 20 times/min.]), Min. 10
5
(10 A 30 V DC [at 20 times/min.])
Conditions
Conditions for operation, transport and storage*
2
Ambient temperature: –50°C to +60°C –58°F to +140°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at rated load)
Unit weight 2 Form C: 50 g 1.76 oz; 4 Form C: 65 g 2.29 oz
1.-(1) Coil temperature rise (2 Form C type)
Tested sample: SP2-DC24V
1.-(2) Coil temperature rise (4 Form C type)
Tested sample: SP4-DC24V
Ambient temperature: 27 to 29°C 81 to 84°F
Coil applied voltage, V
0
10
20
30
40
50
Temperature rise, °C
15 A
10 A
5 A
0 A
19.2 21.6 26.4 28.8 31.2 33.6 36.024.0
Coil applied voltage, V
0
10
20
30
40
50
19.2 21.6 26.4 28.8 31.2 33.6 36.024.0
Temperature rise, °C
10 A
5 A
0 A