PDUB30

2.9kW Single-Phase Hot-Swap PDU, 120V 30A (1
L5-30R, 6 5-15/20R), 2 L5-30P, 10ft & 6ft Cords,
2U Rack-Mount
MODEL NUMBER: PDUB30
Description
Tripp Lite’s Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance
with no interruption of connected server or networking loads. Dual input power cables support PDU
connection to separate Utility and UPS power sources. Manual transfer switch with lighted status
indicators controls the source of power to connected equipment between Utility and UPS. Set the switch
to UPS during normal operation and connected equipment will receive full-time conditioned power from
the UPS. Set the switch to Utility to momentarily power connected equipment from the Utility line cord and
bypass the UPS while the UPS system is removed and replaced with a fresh one. Once the new UPS is
up and running with all data and electrical connections restored, set the switch back to the UPS setting to
once again provide fully-conditioned UPS power to connected equipment.
Features
Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance
with no interruption of connected server or networking loads
PDUB30 is universally compatible with any Tripp Lite or other brand of 100-127V UPS rated up to
3000VA or 2880 watts with a NEMA L5-30P input cable
2U horizontal rackmount form factor compatible with 2 or 4 post racks
Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS
systems (select installations, see manual)
Pair of attached L5-30P PDU input cables connect to separate Utility and UPS power sources
6 5-15/20R and 1 L5-30R outlets support critical networking loads in both Utility and UPS operating
modes
One additional L5-30R pass-through outlet supports UPS input power cord
Highlights
Single phase 30A 120V Hot-
swap PDU
Enables live replacement of a
standard UPS with zero
downtime
2U horizontal rackmount
installation
Compatible with any UPS with a
L5-30P input plug
Manual transfer switch controls
PDU input power source
Pair of L5-30P input cables
connect to separate Utility and
UPS inputs
7 outlets (6 5-15/20 & 1 L5-30R)
Package Includes
Hot-swap PDU System
2U mounting brackets
User manual with warranty
information
1 / 3
Specifications
Dual input power cables support PDU connection to separate Utility and UPS power sources
Manual transfer switch with lighted status indicators controls the source of power to connected
equipment between Utility and UPS
Set the switch to UPS during normal operation and connected equipment will receive full-time
conditioned power from the UPS
Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power
directly from the Utility line cord while the UPS system is removed and replaced with a fresh one
Once the new UPS is up and running with all connections restored, set the switch back to the UPS
setting to once again provide fully-conditioned UPS power to connected equipment
TAA Compliant Version Available - Order Tripp Lite PDUB30TAA
OVERVIEW
UPC Code 037332153890
PDU Type Hot-Swap
OUTPUT
Output Watt Capacity (Watts) 2880
Output Capacity Details 3.05kW (127V), 2.88kW (120V), 2.4kW (100V) / 30A total capacity (Agency de-rated to 24A); 24A max per L5-30R
outlet; 20A max per breakered load bank; 16A max per 5-15/20R outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (6) 5-15/20R; (1) L5-30R
Output Nominal Voltage 100; 120; 127
INPUT
PDU Input Voltage 100; 120; 127
Recommended Electrical Service 30A 120V
Maximum Input Amps 24
PDU Plug Type NEMA L5-30P
Input Cord Length Details Utility input cable (10 ft / 3m) / UPS input cable (6 ft / 1.8m)
Input Phase Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Front Panel LEDs Lighted indicators confirm UPS and Utility switch position and operating mode
Switches Manual 2 position transfer switch offers fast switching between UPS and Utility operating modes in less than 6
milliseconds
2 / 3
© 2018 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:
https://www.tripplite.com/products/product-certification-agencies
PHYSICAL
Minimum Required Rack Depth
(inches)
8.5
Minimum Required Rack Depth (cm) 21.59
Shipping Dimensions (hwd / in.) 12.200 x 20.300 x 6.300
Shipping Dimensions (hwd / cm) 30.99 x 51.56 x 16.00
Shipping Weight (lbs.) 12.0000
Shipping Weight (kg) 5.44
Unit Dimensions (hwd / in.) 3.42 x 17.32 x 3.03
Unit Dimensions (hwd / cm) 8.7 x 44 x 7.7
Unit Weight (lbs.) 7.7
Unit Weight (kg) 3.49
Material of Construction Metal
Form Factors Supported 2U rackmount in 2 or 4 post racks
PDU Form Factor Horizontal (1U)
ENVIRONMENTAL
Storage Temperature Range 5 to 122F (-15 to 50C)
Relative Humidity 5-95% non condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
CERTIFICATIONS
TAA Compliant Option TAA Compliant Version Available - Order Tripp Lite PDUB30TAA
Certifications Tested to UL60950 (USA), CSA (Canada)
WARRANTY
Product Warranty Period
(Worldwide)
2-year limited warranty
3 / 3

PDUB30

Mfr. #:
Manufacturer:
Tripp Lite
Description:
Power Outlet Strips 6)5-15/20R 1)L5-30R HOTSWAP L5-30P INPUT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet