AD586
Rev. G | Page 3 of 16
SPECIFICATIONS
AD586J, AD586K/AD586A, AD586L/AD586B
@ T
A
= 25°C, V
IN
= 15 V, unless otherwise noted. Specifications in boldface are tested on all production units at final electrical test. Results
from those tests are used to calculate outgoing quality levels. All minimum and maximum specifications are guaranteed, although only
those shown in boldface are tested on all production units, unless otherwise specified.
Table 1.
AD586J AD586K/AD586A AD586L/AD586B
Parameter Min Typ Max Min Typ Max Min Typ Max Unit
OUTPUT VOLTAGE 4.980 5.020 4.995 5.005 4.9975 5.0025 V
OUTPUT VOLTAGE
DRIFT
1
0°C to 70°C 25 15 5 ppm/°C
−55°C to +125°C ppm/°C
GAIN ADJUSTMENT
+6
+6
+6
%
−2 −2 −2 %
LINE REGULATION
1
10.8 V < + V
IN
< 36 V
T
MIN
to T
MAX
±100
±100
±100
µV/V
11.4 V < +V
IN
< 36 V
T
MIN
to T
MAX
µV/V
LOAD REGULATION
1
Sourcing 0 mA < I
OUT
< 10 mA
25°C
100
100
100
µV/mA
T
MIN
to T
MAX
100
100
100
µV/mA
Sinking −10 mA < I
OUT
< 0 mA
25°C
400
400
400
µV/mA
QUIESCENT CURRENT 2
3
2
3
2
3
mA
POWER CONSUMPTION 30 30 30 mW
OUTPUT NOISE
0.1 Hz to 10 Hz 4 4 4 µV p-p
Spectral Density, 100 Hz 100 100 100 nV/√Hz
LONG-TERM STABILITY 15 15 15 ppm/1000 hr
SHORT-CIRCUIT
CURRENT-TO-GROUND
45
60
45
60
45
60
mA
TEMPERATURE RANGE
Specified Performance
2
0 70 0
−40
(K grade)
(A grade)
70
+85
0
−40
(L grade)
(B grade)
70
+85
°C
°C
Operating Performance
3
−40 +85 −40 +85 −40 +85 °C
1
Maximum output voltage drift is guaranteed for all packages and grades. CERDIP packaged parts are also 100°C production tested.
2
Lower row shows specified performance for A and B grades.
3
The operating temperature range is defined as the temperature extremes at which the device will still function. Parts may deviate from their specified performance