Maximum ratings LD29300
6/18 DocID9248 Rev 14
4 Maximum ratings
Note: Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these conditions is not implied.
Table 2. Absolute maximum ratings
Symbol Parameter Value Unit
V
I
DC input voltage 30
(1)
1. Above 14 V the device is automatically in shut-down.
V
I
O
Output current Internally limited mA
P
D
Power dissipation Internally limited mW
T
STG
Storage temperature range - 55 to 150 °C
T
OP
Operating junction temperature range - 40 to 125 °C
Table 3. Thermal data
Symbol Parameter P²PAK/A Unit
R
thJA
Thermal resistance junction-ambient 60 °C/W
R
thJC
Thermal resistance junction-case 3 °C/W