T5400SAW Components
Digital barometric pressure sensor
Preliminary data
9 April 25, 2013
Please read
cautions and warnings and
important notes
at the end of this document.
Cautions and warnings
■ Immersion of the sensor in liquids e.g. a flux cleaning process is not possible.
■ For optimum performance avoid direct light exposure.
■ Media compatibility with the pressure sensor must be ensured. Do not expose the sensor to corrosive
or explosive gases.
Pressure conversion table
Annotations
■ bar Bar
■ Pa Pascal (≡ 1 N/m
2
)
■ hPa Hecto-Pascal (≡ 1 mbar)
■ mmHg mm column of mercury (≡ 1 Torr)
■ psi Pounds per square inch (≡ 1 lbf/in
2
)
Assembly conditions
Solder reflow profile According to EPCOS specification S_6001
Max. number of reflows 3
Max. peak temperature 260 °C
Moisture sensitivity level MSL 3
Unit bar mbar Pa hPa kPa mmHg psi
1 bar 1 1000 100000 1000 100 750.063 14.504
1 mbar 0.001 1 100 1 0.1 0.750 0.0145
1 Pa 0.00001 0.01 1 0.01 0.001 0.0075 0.000145
1 hPa 0.001 1 100 1 0.1 0.750 0.0145
1 kPa 0.01 10 1000 10 1 7.5006 0.145
1 mmHg 0.00133 1.3332 133.322 1.3332 0.13332 1 0.01933
1 psi 0.0689476 68.9476 6894.76 68.9476 6.89476 51.7151 1