https://www.phoenixcontact.com/us/products/2902005
09/06/2016Page3/10
Isolation amplifier-MINI MCR-2-NAM-2RO-PT-2902005
Technical data
General
Rated insulation voltage 300 V (effective)
Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
Color gray
Housing material PBT
Mounting position any
Assembly instructions
The T connector can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715.
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
GL GL applied for
EMC data
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Designation Conducted interferences
Standards/regulations EN61000-4-6
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Standards/regulations EN 61000-4-2
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Designation Conducted interferences
Standards/regulations EN61000-4-6
Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X