SPECIFICATION
LPP-100-3.3 LPP-100-5 LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
LEAKAGE CURRENT
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A
0 ~ 4.2A
100.8W
3.8A 2.1A
0 ~ 20A 0 ~ 20A 0 ~ 13.3A 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 3.8A 0 ~ 2.1A
66W 100W 101.25W 102W 101.25W 100.5W 102.6W 100.8W
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
±2.0% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0%
±2.0%
±1.0%
±2.0%
±1.0% ±0.5%±0.5%±0.5%±0.5% ±0.5% ±0.5%
600ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
28ms/230VAC 28ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
69%
1.7A/115VAC 0.75A/230VAC
75% 76% 79% 79% 80% 83% 83% 83%
COLD START 30A/230VAC
<2mA / 240VAC
105 ~ 150% rated output power
3.8 ~ 4.45V 5.75 ~ 6.75V 8.6 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V
17.25 ~ 20.25V
27.6 ~ 32.4V 31 ~ 36.45V 55.2 ~ 64.8V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
20 ~ 90% RH non-condensing
-10 ~ +60 (Refer to "Derating Curve")℃
-20 ~ +85 , 10 ~ 95% RH℃
±℃ ℃)0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
224.3Khrs min. MIL-HDBK-217F (25 )℃
222*62*33.6mm (L*W*H)
0.51Kg; 24pcs/13.9Kg/1.39CUFT
File Name:LPP-100-SPEC 2018-01-12
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
, EAC TP TC 004
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020
100W Single Output with PFC Function
LPP-100 series
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
■
Features :
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
EFFICIENCY(Typ.)
INPUT
INRUSH CURRENT (Typ.)
AC CURRENT (Typ.)
EMC IMMUNITY
EMC EMISSION