Spec No.JELF243A-9128A-01 P1/8
MURATA MFG.CO., LTD
Reference Only
CHIP COIL (CHIP INDUCTORS) LQH2HPZ□□□□GRL
Murata Standard Reference Specification【AEC-Q200】
1.Scope
This reference specification applies to Chip coil (Chip Inductors) LQH2HPZ_GR Series for Automotive Electronics
based on AEC-Q200 except for Power train and Safety.
2.Part Numbering
(ex) LQ H 2H P Z 1R0 M G R L
Product ID
Structure
Dimension
Applications Category Inductance Tolerance Dimension
Other Packaging
(L×W)
and
(T)
L:φ180Taping
Characteristics
3.Rating
Operating Temperature Range
(Ambient temperature; Self-temperature rise is not included) -40 to +105°C
(Product temperature; Self- temperature rise is included) -40 to +125°C
Storage Temperature Range. -40 to +105°C
Customer
Part
Number
MURATA
Part Number
Inductance
DC
Resistance
(Ω)
Self
Resonant
Frequency
(MHz min)
Rated Current (mA)
ESD
5A: 8kV
∗1 Based on
Inductance
change
∗2 Based on
Temperature rise
(μH)
Tolerance
(%)
∗3 Ambient
temperature
(85 )℃
∗4 Ambient
temperature
(105 )℃
LQH2HPZR47MGRL
0.47
M:±20
0.045±20% 120 2900 2520 1470
5A
LQH2HPZR68MGRL
0.68
0.055±20% 110 2430 2330 1350
LQH2HPZ1R0MGRL
1.0
0.068±20% 100 2130 2100 1200
LQH2HPZ1R5MGRL
1.5
0.087±20% 90 1700 1850 1110
LQH2HPZ2R2MGRL
2.2
0.134±20% 80 1550 1470 850
LQH2HPZ3R3MGRL
3.3
0.225±20% 70 1230 1100 660
LQH2HPZ4R7MGRL
4.7
0.300±20% 50 1090 1000 570
LQH2HPZ6R8MGRL
6.8
0.395±20% 40 830 860 490
LQH2HPZ100MGRL
10
0.560±20% 30 700 710 430
LQH2HPZ150MGRL
15
0.925±20% 20 570 560 310
LQH2HPZ220MGRL
22
1.360±20% 15 460 430 250
∗1:When applied Rated current to the Products , Inductance will be within ±30% of initial inductance value range.
∗2:
Keep the temperature(ambient temperature plus self-generation of heat) under 125 . ℃
∗3: When applied rated current to the Products, temperature rise caused by self-generated heat shall be limited to 40 max.℃
(Ambient temperature 85℃).
∗4:When applied rated current to the Products,temperature rise caused by self-generated heat shall be limited to 20 ℃
max.(Ambient temperature 85-105℃).
4. Testing Conditions
《Unless otherwise specified》 《In case of doubt》
Temperature : Ordinary Temperature (15 to 35°C) Temperature
: 20 ± 2°C
Humidity
: Ordinary Humidity (25 to 85 %(RH) Humidity : 60 to 70 %(RH)
Atmospheric Pressure : 86 to 106 kPa