SPEC NO: DSAN2911 REV NO: V.7B DATE: JUL/01/2016 PAGE: 2 OF 5
APPROVED: Wynec CHECKED: Allen Liu DRAWN: L.T.Zhang ERP: 1203013982
Selection Guide
Absolute Maximum Ratings at TA=25°C
Electrical / Optical Characteristics at TA=25°C
Part No. Emitting Color (Material) Lens Type
Iv (mcd) [2]
@ 5mA
iewing
Angle [1]
Min. Typ. 2θ1/2
APG1005PBC-T-5MAV Blue (InGaN) Water Clear 20 28
140
°
Symbol Parameter Emitting Color Typ. Max. Units Test Conditions
λpeak Peak Wavelength Blue 461 nm I
F=5mA
λD [1] Dominant Wavelength Blue 467 nm I
F=5mA
Δλ1/2 Spectral Line Half-width Blue 22 nm I
F=5mA
V
F [2] Forward Voltage Blue 2.9 3.1 V IF=5mA
I
R Reverse Current Blue 50 uA VR=5V
Parameter Values Units
Power dissipation 32 mW
DC Forward Current 10 mA
Peak Forward Current [1] 50 mA
Reverse Voltage 5 V
Operating Temperature -40°C To +85°C
Storage Temperature -40°C To +85°C
Electrostatic Discharge Threshold (HBM)
1000 V
Notes:
1. θ1/2 is the angle from optical centerline where the luminous intensity is 1/2 of the optical peak value.
2. Luminous intensity / luminous Flux: +/-15%.
3. Luminous intensity value is traceable to CIE127-2007 standards.
Notes:
1. Wavelength: +/-1nm.
2. Forward Voltage: +/-0.1V.
3. Wavelength value is traceable to CIE127-2007 standards.
4. Excess driving current and/or operating temperature higher than recommended conditions may result in severe light degradation or
premature failure.
Notes:
1. 1/10 Duty Cycle, 0.1ms Pulse Width.
2. Relative humidity levels maintained between 40% and 60% in production area are recommended to avoid the build-up of static electricity – Ref
JEDEC/JESD625-A and JEDEC/J-STD-033.