Features
Performance specied for common IPM applications
over industrial temperature range: -40°C to 125°C
Fast maximum propagation delays
- t
PHL
& t
PLH
= 550 ns
Minimized Pulse Width Distortion (PWD = 370 ns)
Very high Common Mode Rejection (CMR):
15 kV/µs at V
CM
= 1500 V
CTR > 44% at I
F
= 10 mA
Safety approval
- UL recognized per UL1577 (le no. E55361)
3750 V
rms
for 1 minute
- CSA Approved
- IEC/EN/DIN EN 60747-5-5
Applications
Industrial Intelligent Power Module isolation for
battery management system and motor control
Isolated IGBT/MOSFET gate drive
AC and brushless dc motor drives
Industrial inverters for power supplies and motor
controls
The connection of a 0.1 µF bypass capacitor between pins 4 and 6 is
recommended.
Truth Table
LED V
O
ON
L
OFF
H
Description
The ACPL-M46U-000E consists of a AlGaAs optically
coupled to an integrated high gain photo detector. Mini-
mized propagation delay dierence between devices
makes these optocouplers excellent solutions for im-
proving industrial inverter eciency through reduced
switching dead time.
Specication and performance plots are given for typical
IPM applications.
Avago R
2
Coupler isolation products provide the rein-
forced insulation and reliability needed for critical in
automotive and high temperature industrial applications.
Functional Diagram
ACPL-M46U-000E
Wide Operating Temperature Intelligent Power Module Optocoupler
with R
2
Coupler™ Isolation and 5 Lead Small Outline
Data Sheet
Lead (Pb) Free
RoHS 6 fully
compliant
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
6
5
4
1
3
SHIELD
V
CC
V
OUT
GND
CATHODE
ANODE
2
Ordering Information
Part Number
Options
Package
Surface
Mount
Tape
& Reel
IEC/EN/DIN
EN 60747-5-5 QuantityRoHS Compliant
ACPL-M46U
-000E
SO-5
X X 100 per tube
-500E X X X 1500 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example 1:
ACPL-M46U-500E to order product of SO-5 Surface Mount package in Tape and Reel packaging with RoHS compli-
ant.
Example :
ACPL-M46U-000E to order product of SO-5 Surface Mount package in tube packaging with RoHS compliant.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
Package Outline Drawing
ACPL-M46U-000E Small Outline SO-5 Package (JEDEC MO-155)
M46U
YWW
7.0 ± 0.2
(0.276 ± 0.008)
2.5 ± 0.1
(0.098 ± 0.004)
0.102 ± 0.102
(0.004 ± 0.004)
4.4 ± 0.1
(0.173 ± 0.004)
1.27
(0.050)
BSC
0.216 ± 0.038
(0.0085 ± 0.0015)
0.71
(0.028)
MIN
0.4 ± 0.05
(0.016 ± 0.002)
3.6 ± 0.1*
(0.142 ± 0.004)
DIMENSIONS IN MILLIMETERS (INCHES)
* MAXIMUM MOLD FLASH ON EACH SIDE IS 0.15 mm (0.006)
NOTE: FLOATING LEAD PROTRUSION IS 0.15 mm (6 mils) MAX.
7° MAX.
MAX. LEAD COPLANARITY
= 0.102 (0.004)
LAND PATTERN RECOMMENDATION
8.27
(0.325)
2.0
(0.080)
2.5
(0.10)
1.3
(0.05)
0.64
(0.025)
4.4
(0.17)
3
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
Description Symbol Characteristic Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 V
rms
I – IV
I – III
I – II
Climatic Classication 55/125/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
567 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test with t
m
=1 sec, Partial discharge < 5 pC
V
PR
1063 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6=V
PR
, Type and Sample Test, t
m
=10 sec, Partial discharge < 5 pC
V
PR
907 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 60 sec) V
IOTM
6000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
EN/DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test proles.
Regulatory Information
The ACPL-M46U-000E is approved by the following organizations:
UL
Approved under UL 1577, component recognition pro-
gram up to V
ISO
= 3750 V
RMS
CSA
Approved under CSA Component Acceptance Notice #5
IEC/EN/DIN EN 60747-5-5
Approved under:
IEC 60747-5-5:2007
EN 60747-5-5:2011
Recommended Reflow Soldering Profile
Recommended reow soldering condition are per JEDEC Standard J-STD-020 (latest revision). Non-halide ux should
be used.

ACPL-M46U-500E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Logic Output Optocouplers 1MBd 30k V/us
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS