Technical specifications
Maximum continuous operating voltage
250 VAC, 50/60 Hz
Operating frequency
DC to 400 Hz
Rated currents
1 to 10 A @ 40°C max.
High potential test voltage
P –> PE 2000 VAC for 2 sec
P –> N 760 VAC for 2 sec
P –> N 250 VAC for 2 sec (Z types)
Temperature range (operation and storage)
-25°C to +100°C (25/100/21)
Flammability corresponding to
UL 94 V-2 or better
Design corresponding to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Surge pulse protection (Z type)
2 kV, IEC 61000-4-5
MTBF @ 40°C/230 V (Mil-HB-217F)
710,000 hours
Approvals
Features and benefits
FN 332 filters are designed for easy and fast chassis
mounting
FN 332 filters are also available with integrated surge
pulse protection to safeguard sensitive electrical
equipment
All FN 332 single-phase filters provide a good
attenuation performance, based on chokes with
high saturation resistance and excellent thermal
behavior
Chokes with high saturation resistance and high
inductivity
Surge pulse protection
Custom-specific versions on request
Typical applications
Electrical and electronic equipment
Consumer goods
Household equipment
Power supplies
Office automation equipment
Datacom equipment
Industrial equipment auxiliary supply
Typical electrical schematic
2 EMC/EMI Products Schaffner Group Datasheets 2017
Filter selection table
Filter Rated current Leakage current* Inductance Capacitance Surge Energy Input/Output Weight
@ 40°C (25°C) @ 230 VAC/50 Hz L Cx Cy current absorption connections
[A] [μA] [mH] [nF] [nF] [A] [J] [g]
FN 332-1-05 1 (1.2) 340 10 15 2.2 -05 65
FN 332-3-05 3 (3.6) 340 2 15 2.2 -05 65
FN 332-6-05 6 (7.3) 340 0.8 15 2.2 -05 65
FN 332-10 A-05 10 (12) 340 0.5 15 2.2 -05 70
FN 332 Z-1-05 1 (1.2) 340 10 15 2.2 1200 26 -05 65
FN 332 Z-3-05 3 (3.6) 340 2 15 2.2 1200 26 -05 65
FN 332 Z-6-05 6 (7.3) 340 0.8 15 2.2 1200 26 -05 65
FN 332 Z-10-05 10 (12) 340 0.5 15 2.2 1200 26 -05 70
* Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Typical filter attenuation
Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym
1 A types
3 and 6 A types
10 A types
3 EMC/EMI Products Schaffner Group Datasheets 2017
Mechanical data
FN 332
Dimensions
1 to 10 A types Tolerances
A 65.6 ±0.5
B 45 ±0.5
C 24.8 ±0.5
D 28 ±0.5
E 40 ±0.5
F 37 ±0.4
G 12.5 ±0.2
H 9.6 ±0.2
I 18.7 ±0.5
J 14 ±0.5
K 3.5
L 3.9
M 0.5
N 6.3 x 0.8
All dimensions in mm; 1 inch = 25.4 mm
Tolerances according: ISO 2768-m/EN 22768-m
Please visit www.schaffner.com to find more details on filter connectors

FN332-3-05

Mfr. #:
Manufacturer:
Schaffner
Description:
Power Line Filters 3A FASTON CHASSIS MNT PERFORMANCE FLTR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union