THD< 20% when output loading 75% at 115VAC/230VAC input≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
42 units (circuit breaker of type B) / 42 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL PLC-45-12 PLC-45-15 PLC-45-20 PLC-45-24 PLC-45-27 PLC-45-36 PLC-45-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
12V 15V 20V 24V 27V 36V 48V
3.8A 3A 2.3A 1.9A 1.7A 1.25A 0.95A
0 ~ 3.8A 0 ~ 3A 0 ~ 2.3A 0 ~ 1.9A 0 ~ 1.7A 0 ~ 1.25A 0 ~ 0.95A
45.6W 45W 46W 45.6W 45.9W 45W 45.6W
2Vp-p 2.4Vp-p 1.8Vp-p 2.7Vp-p 2.7Vp-p 3.6Vp-p 4.6Vp-p
±10%
±3.0%
±5.0%
500ms / 230VAC 1200ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.92/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
83.5% 85% 86.5% 86.5% 86.5% 87.5% 87.5%
13.8 ~ 16V 17.5 ~ 21V 22.8 ~ 25V 28 ~ 32V 31 ~ 35V 41 ~ 46V 54 ~ 60V
0.55A/115VAC 0.25A/230VAC
COLD START 35A(twidth=50 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
-30 ~ +50 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
515Khrs min. MIL-HDBK-217F (25 )℃
181.5*62*35mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Please refer to "DRIVING METHODS OF LED MODULE".
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
0.41Kg; 30pcs/13.3Kg/0.67CUFT
45W Single Output LED Power Supply
Universal AC input / Full range
Adjustable output voltage and current level
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C
( 75% load)≧
Class 2 power unit
ass LPSP
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 years warranty
■
Features :
PLC-45 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3≧
,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A,EAC TP TC 020
95 ~ 110%
Protection type : Shut down o/p voltage, re-power on to recover
..
M M
110
LPS
SELV
11.25 ~15V 15 ~ 20V 18 ~24V 20.25 ~27V 27 ~ 36V 36 ~ 48V9 ~ 12V
CONSTANT CURRENT REGION Note.6
VOLTAGE ADJ. RANGE Note.5
CURRENT ADJ. RANGE
Note.5
11.5 ~ 13V
2.85 ~ 3.914A
14.5 ~ 16.2V
2.25 ~ 3.1A
19.5 ~ 22V
1.725 ~ 2.37A
24 ~ 26V
1.425 ~1.957A
25 ~ 30V
1.275 ~ 1.75A
32.5 ~ 39V
0.938 ~ 1.288A
43.6 ~ 51.8V
0.713 ~ 0.979A
EMC IMMUNITY
EMC EMISSION
Ul1310, TUV EN61347-1, EN61347-2-13, GB19510.14, GB19510.1, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved
,EAC TP TC 004
File Name:PLC-45-SPEC 2018-01-11
S
&
E
( for 48V only)
( except for 48V )