Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
“ZNR” Transient/Surge Absorbers (Type D)
Application Note for Safety Standards (For Series E)
●
Approvals products lists in "Reference Guide to Standard Products"
●
UL and VDE : Registered in "Type Name" , it isn’t registered in "Panasonic Part No."
●
CQC : Registered in "Panasonic Part No."
●
"Rated Voltages" are specifi ed for UL recognized components in list shown below.
✽: 5 series is blank, 7 series is 7, 8 series is 8, 10 series is 10, 11 series is 11, 14 series is 14
Type Name
Maximum Allowable Voltage Rated Voltage (Vrms)
ACrms (V) DC (V) UL1449
E
✽
201 130 170 118
E
✽
221 140 180 127
E
✽
241 150 200 136
E
✽
271 175 225 159
E
✽
331 210 270 189
E
✽
361 230 300 209
E
✽
391 250 320 227
E
✽
431 275 350 250
E
✽
471 300 385 272
E
✽
511 320 410 291
E
✽
561 350 450 320
E
✽
621 385 505 350
E
✽
681 420 560 381
E
✽
751 460 615 418
E
✽
821 510 670 463
E
✽
911 550 745 500
E
✽
102 625 825 568
E
✽
112 680 895 600
The AC Rated Voltage and Maximum Allowable Voltage
Jan. 201503