1
Features
Single Supply Voltage, Range 3V to 3.6V
3-volt Only Read and Write Operation
Software Protected Programming
Low-power Dissipation
15mAActiveCurrent
40 µA CMOS Standby Current
Fast Read Access Time – 120 ns
Sector Program Operation
Single-cycle Reprogram (Erase and Program)
512 Sectors (128 Bytes/Sector)
Internal Address and Data Latches for 128 Bytes
Fast Sector Program Cycle Time – 20 ms Max.
Internal Program Control and Timer
DATA Polling for End of Program Detection
Typical Endurance > 10,000 Cycles
CMOS and TTL Compatible Inputs and Outputs
Commercial and Industrial Temperature Ranges
Description
The AT29LV512 is a 3-volt-only in-system Flash programmable erasable read-only
memory (PEROM). Its 512K of memory is organized as 65,536 words by 8 bits. Man-
ufactured with Atmels advanced nonvolatile CMOS technology, the device offers
access times to 120 ns with power dissipation of just 54 mW over the commercial tem-
perature range. When the device is deselected, the CMOS standby current is less
than 40 µA. The device endurance is such that any sector can typically be written to in
excess of 10,000 times.
512K (64K x 8)
3-volt Only
Flash Memory
AT29LV512
Rev. 0177M–05/02
Pin Configurations
Pin Name Function
A0 - A15 Addresses
CE
Chip Enable
OE
Output Enable
WE
Write Enable
I/O0 - I/O7 Data Inputs/Outputs
NC No Connect
TSOP Top View
Type 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
A11
A9
A8
A13
A14
NC
WE
VCC
NC
NC
A15
A12
A7
A6
A5
A4
OE
A10
CE
I/O7
I/O6
I/O5
I/O4
I/O3
GND
I/O2
I/O1
I/O0
A0
A1
A2
A3
PLCC Top View
5
6
7
8
9
10
11
12
13
29
28
27
26
25
24
23
22
21
A7
A6
A5
A4
A3
A2
A1
A0
I/O0
A14
A13
A8
A9
A11
OE
A10
CE
I/O7
4
3
2
1
32
31
30
14
15
16
17
18
19
20
I/O1
I/O2
GND
I/O3
I/O4
I/O5
I/O6
A12
A15
NC
NC
VCC
WE
NC
2
AT29LV512
0177M05/02
To allow for simple in-system reprogrammability, the AT29LV512 does not require high
input voltages for programming. Three-volt-only commands determine the operation of
the device. Reading data out of the device is similar to reading from an EPROM. Repro-
gramming the AT29LV512 is performed on a sector basis; 128 bytes of data are loaded
into the device and then simultaneously programmed.
During a reprogram cycle, the address locations and 128 bytes of data are captured at
microprocessor speed and internally latched, freeing the address and data bus for other
operations. Following the initiation of a program cycle, the device will automatically
erase the sector and then program the latched data using an internal control timer. The
end of a program cycle can be detected by DATA
polling of I/O7. Once the end of a pro-
gram cycle has been detected, a new access for a read or program can begin.
Block Diagram
Device Operation
READ: The AT29LV512 is accessed like an EPROM. When CE and OE are low and
WE
is high, the data stored at the memory location determined by the address pins
is asserted on the outputs. The outputs are put in the high impedance state whenever
CE
or OE is high. This dual-line control gives designers flexibility in preventing bus
contention.
SOFTWARE DATA PROTECTION PROGRAMMING: The AT29LV512 has 512 individ-
ual sectors, each 128 bytes. Using the software data protection feature, byte loads are
used to enter the 128 bytes of a sector to be programmed. The AT29LV512 can only be
programmed or reprogrammed using the software data protection feature. The device is
programmed on a sector basis. If a byte of data within the sector is to be changed, data
for the entire 128-byte sector must be loaded into the device. The AT29LV512 automat-
ically does a sector erase prior to loading the data into the sector. An erase command is
not required.
Software data protection protects the device from inadvertent programming. A series of
three program commands to specific addresses with specific data must be presented to
the device before programming may occur. After writing the three-byte command
sequence (and after t
WC
), the entire device is protected. The same three program com-
mands must begin each program operation. All software program commands must obey
the sector program timing specifications. Power transitions will not reset the software
data protection feature; however, the software feature will guard against inadvertent
program cycles during power transitions.
3
AT29LV512
0177M05/02
Any attempt to write to the device without the 3-byte command sequence will start the
internal write timers. No data will be written to the device; however, for the duration of
t
WC
, a read operation will effectively be a polling operation.
After the software data protections 3-byte command code is given, a byte load is per-
formed by applying a low pulse on the WE
or CE input with CE or WE low (respectively)
and OE
high. The address is latched on the falling edge of CE or WE, whichever occurs
last. The data is latched by the first rising edge of CE
or WE.
The 128 bytes of data must be loaded into each sector. Any byte that is not loaded dur-
ing the programming of its sector will be erased to read FFh. Once the bytes of a sector
are loaded into the device, they are simultaneously programmed during the internal pro-
gramming period. After the first data byte has been loaded into the device, successive
bytes are entered in the same manner. Each new byte to be programmed must have its
high-to-low transition on WE
(or CE) within 150 µs of the low-to-high transition of WE (or
CE
) of the preceding byte. If a high-to-low transition is not detected within 150 µs of the
last low-to-high transition, the load period will end and the internal programming period
will start. A7 to A15 specify the sector address. The sector address must be valid during
each high-to-low transition of WE
(or CE). A0 to A6 specify the byte address within the
sector. The bytes may be loaded in any order; sequential loading is not required. Once a
programming operation has been initiated, and for the duration of t
WC
, a read operation
will effectively be a polling operation.
HARDWARE DATA PROTECTION: Hardware features protect against inadvertent
programs to the AT29LV512 in the following ways: (a) V
CC
sense if V
CC
is below 1.8V
(typical), the program function is inhibited; (b) V
CC
power on delay once V
CC
has
reached the V
CC
sense level, the device will automatically time out 10 ms (typical)
before programming; (c) Program inhibit holding any one of OE
low, CE high or WE
high inhibits program cycles; and (d) Noise filter pulses of less than 15 ns (typical) on
the WE
or CE inputs will not initiate a program cycle.
INPUT LEVELS: Whileoperatingwitha3.3V±10% power supply, the address inputs
and control inputs (OE
,CEand WE) may be driven from 0 to 5.5V without adversely
affecting the operation of the device. The I/O lines can only be driven from 0 to 3.6 volts.
PRODUCT IDENTIFICATION: The product identification mode identifies the device
and manufacturer as Atmel. It may be accessed by hardware or software operation. The
hardware operation mode can be used by an external programmer to identify the correct
programming algorithm for the Atmel product. In addition, users may wish to use the
software product identification mode to identify the part (i.e., using the device code), and
have the system software use the appropriate sector size for program operations. In this
manner, the user can have a common board design for 256K to 4-megabit densities
and, with each densitys sector size in a memory map, have the system software apply
the appropriate sector size.
For details, see Operating Modes (for hardware operation) or Software Product Identifi-
cation. The manufacturer and device code is the same for both modes.
DATA
POLLING: The AT29LV512 features DATA polling to indicate the end of a pro-
gram cycle. During a program cycle an attempted read of the last byte loaded will result
in the complement of the loaded data on I/O7. Once the program cycle has been com-
pleted, true data is valid on all outputs and the next cycle may begin. DATA
polling may
begin at any time during the program cycle.

AT29LV512-15TI

Mfr. #:
Manufacturer:
Description:
IC FLASH 512K PARALLEL 32TSOP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: