PS8602,PS8602L
SPECIFICATION OF VDE MARKS LICENSE DOCUMENT (VDE0884)
Parameter Symbol Speck Unit
Application classification (DIN VDE 0109)
for rated line voltages ≤ 300 V
r.m.s.
for rated line voltages ≤ 600 V
r.m.s.
IV
III
Climatic test class (DIN IEC 68 Teil 1/09.80) 55/100/21
Dielectric strength
maximum operating isolation voltage
Test voltage (partial discharge test, procedure a for type test and random test)
U
pr = 1.2 × UIORM, Pd < 5 pC
U
IORM
Upr
890
1 068
V
peak
Vpeak
Test voltage (partial discharge test, procedure b for all devices)
U
pr = 1.6 × UIORM, Pd < 5 pC
U
pr 1 424 Vpeak
Highest permissible overvoltage UTR 8 000 Vpeak
Degree of pollution (DIN VDE 0109) 2
Clearance distance > 7.0 mm
Creepage distance > 7.0 mm
Comparative tracking index (DIN IEC 112/VDE 0303 part 1) CTI 175
Material group (DIN VDE 0109) III a
Storage temperature range Tstg –55 to +150 °C
Operating temperature range TA –55 to +100 °C
Isolation resistance, minimum value
V
IO = 500 V dc at TA = 25 °C
V
IO = 500 V dc at TA MAX. at least 100 °C
Ris MIN.
Ris MIN.
10
12
10
11
Ω
Ω
Safety maximum ratings (maximum permissible in case of fault, see thermal
derating curve)
Package temperature
Current (input current I
F, Psi = 0)
Power (output or total power dissipation)
Isolation resistance
V
IO = 500 V dc at TA = 175 °C (Tsi)
Tsi
Isi
Psi
Ris MIN.
175
400
700
10
9
°C
mA
mW
Ω
Data Sheet PN10263EJ01V0DS
12