date 04/21/2015 │ page 2 of 5CUI Inc │ SERIES: V78W-500 │ DESCRIPTION: DC-DC CONVERTER
INPUT
parameter conditions/description min typ max units
operating input voltage
3, 5, 6.5 V models
9 V model
12 V model
15 V model
24 V model
9
14
17
20
36
48
48
48
48
48
72
72
72
72
72
Vdc
Vdc
Vdc
Vdc
Vdc
OUTPUT
parameter conditions/description min typ max units
line regulation measured from low line to high line ±0.4 ±1.0 %
load regulation measured from 10% to full load ±0.3 ±0.6 %
voltage accuracy at 100% load ±2 ±3 %
switching frequency 100% load 120 800 kHz
temperature coefcient -40°C ~ +85°C ambient ±0.015 %/°C
quiescent current Vin = nominal, min. load 1 5 mA
tendencies load at 10% to 100% load
1.0
±100
1.5
mV
ms
max capacitance load 100 µF
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection continuous, automatic recovery
short circuit input power Vin = nominal 0.72 1.2 W
thermal shutdown 160 °C
current limit Vin = nominal 700 1200 mA
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
thermal resistance 60 °C/W
EMI/EMC
EN55022, class B (refer to page 4), IEC/EN 61000-4-2 level 4
RoHS compliant yes
MTBF
25°C (MIL-HDBK-217K)
71°C (MIL-HDBK-217K)
3,500,000
1,500,000
hours
hours
ENVIRONMENTAL
parameter conditions/description min typ max units
case operating temperature 65 100 °C
operating temperature power derating above 71°C -40 85 °C
storage temperature -55 125 °C
storage humidity non-condensing 95 %