2981729

© PHOENIX CONTACT - 09/2007
102987_01_en
INTERFACE
PSR-SCP- 24DC/URD3/4X1/2X2/T2
PSR-SPP- 24DC/URD3/4X1/2X2/T2
Data Sheet
Description
The PSR-...- 24DC/URD3/4X1/2X2/T2 safety relay can be
used as a contact extension block in safety circuits
according to DIN EN 60204-1/VDE 0113-1.
The device has an interface for the T-BUS DIN rail
connector. This interface can be used for single-channel
control and monitoring. Alternatively, the device can also be
operated in single-channel mode via a contact on the basic
device.
Depending on the external wiring, up to safety category 3
according to EN 954-1 can be achieved.
The relay has four enabling current paths, one signaling
current path, and one confirmation path. The contacts drop
with at least a 2 second delay according to stop category 1
(DIN EN 60204-1/VDE 0113-1).
The extension unit can be used as a contact multiplier for
emergency stop relays and two-hand controls.
Features
Contact extension block
Safety category 3 according to EN 954-1
Plug-in screw or spring-cage connection terminal
blocks
Single-channel wiring
Safe isolation
Housing width 22.5 mm
Four enable contacts, one alarm contact, and one
confirmation contact
Observe the safety instructions on page 4.
Make sure you always use the latest documentation.
It can be downloaded at www.download.phoenixcontact.com
.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
This data sheet is valid for all products listed on the following page:
Safety Relay as a Contact Extension Block
With Off-Delay Contacts
PSR-...- 24DC/URD3/4X1/2X2/T2
102987_01_en PHOENIX CONTACT 2
Ordering Data
Technical Data
Safety Relay
Description Type Order No. Pcs./Pck.
Safety relay as a contact extension block with off-delay contacts, with screw
connection
PSR-SCP- 24DC/URD3/4X1/2X2/T2 2981703 1
Safety relay as a contact extension block with off-delay contacts, with spring-
cage connection
PSR-SPP- 24DC/URD3/4X1/2X2/T2 2981729 1
Accessories
Description Type Order No. Pcs./Pck.
DIN rail connector, yellow, for PSR applications PSR-TBUS 2890425 50
Terminating connector PSR-TBUS-TP 2981716 50
Documentation
Description Type Order No. Pcs./Pck.
Application manual for PSR safety relays UM EN SAFETY RELAY APPLICATION 2888712 1
Input Data
Nominal input voltage U
N
24 V DC
Permissible range 0.85 ... 1.1 x U
N
Typical current consumption at U
N
84 mA
Typical response time (K1, K2) 20 ms
Release time (K1, K2) 2 s +50%
Recovery time 1 s, approximately
Surge protection Suppressor diode
Status indicators (K1, K2, Power) Green LED
Output Data
Contact type: Positively driven contact assembly Class A according to
EN 50205
4 enabling current paths, 1 signaling current path, 1 confirmation path
Contact material Silver tin oxide (AgSnO
2
)
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 15 V AC/DC
Limiting continuous current
N/O contact
N/C contact (65-66)
6 A
3 A
I
TH
2
= I
1
2
+ I
2
2
+ ... I
N
2
50 A
2
Maximum inrush current
N/O contact
N/C contact (65-66)
6 A
3 A
Minimum switching current 25 mA
Maximum shutdown power
24 V DC
48 V DC
110 V DC
220 V DC
250 V AC
Ohmic load
τ = 0 ms
144 W (72 W)
1
288 W (144 W)
1
77 W
88 W
1500 VA (750 VA)
1
Inductive load τ = 40 ms
48 W
40 W
35 W
33 W
Minimum switching power 0.4 W
PSR-...- 24DC/URD3/4X1/2X2/T2
102987_01_en PHOENIX CONTACT 3
Mechanical service life 10
7
cycles, approximately
Switching capacity according to DIN EN 60947-5-1/VDE 0660-200 Cycles DC13 AC15
3600/h: 24 V DC 3 A
230 V AC 3 A
360/h: 24 V/6 A
230 V/5 A
Short-circuit protection of the output circuits, external
Enabling current paths
Signaling current path
NEOZED 10 A gL/gG
NEOZED 4 A gL/gG
1
The maximum values given in brackets apply to N/C contacts 65-66.
Output Data (Continued)
General Data
Permissible ambient operating temperature -20°C ... +55°C
Nominal operating mode 100% operating factor
Degree of protection according to VDE 0470-1
Housing
Connection terminal blocks
Installation location
IP20
IP20
IP54, minimum
Mounting position Any
Air and creepage distances between the circuits
Basic insulation
1
According to DIN EN 50178:1998-04
Impulse voltage withstand level 4 kV
Pollution degree 2
Surge voltage category III
Dimensions (W x H x D)
Screw connection
Spring-cage connection
22.5 mm x 114.5 mm x 99 mm
22.5 mm x 114.5 mm x 112 mm
Conductor cross-section
Screw connection
Spring-cage connection
0.2 mm
2
... 2.5 mm
2
0.2 mm
2
... 1.5 mm
2
Stripping length
Screw connection
Spring-cage connection
7 mm
8 mm
Housing material Polyamide PA, not reinforced
1
Safe isolation, reinforced insulation, and 6 kV between the input circuit/N/C contacts and the enable contact current paths.
Tests/Approvals
BG/TÜV
UL/CUL

2981729

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
General Purpose Relays PSRSPP24DCURD34X12X2 EXPAN W/SPRING TERM
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet