HIH-4602-L Series
2 www.honeywell.com/sensing
Table 1. Performance Specifications (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
Parameter Minimum Typical Maximum Unit Specific
Note
Interchangeability (first order curve) – – – – –
0% RH to 59% RH -5 – 5 % RH –
60% RH to 100% RH -8 – 8 % RH –
Accuracy (best fit straight line) -3.5 – +3.5 % RH 1
Hysterisis – 3 – % RH –
Repeatability – ±0.5 – % RH –
Settling time – – 70 ms –
Response time (1/e in slow moving air) – 30 – s –
Stability (at 50% RH in one year) – 1.2 – % RH –
Voltage supply 4 – 5.8 Vdc –
Current supply – 200 500 µA –
Output voltage temp. coefficient at 50% RH, 5 V – -4 – mV/°C –
Voltage output (1st order curve fit) V
OUT
= (V
SUPPLY
)(0.0062(sensor RH) + 0.16), typical at 25 °C 2
Temperature compensation True RH = (sensor RH)/(1.0546-0.00216T), T in °C
Operating temperature -40[-40] See Figure 1. 85[185] °C[°F] –
Operating humidity 0 See Figure 1. 100 % RH 3
Storage temperature -40[-40] See Figure 2. 125[257] °C[°F] –
Storage humidity See Figure 2. % RH 3
Specific Notes:
1. Applies to HIH-4602-L-CP only.
2. Device is calibrated at 5 Vdc and 25 ºC.
3. Non-condensing environment.
General Notes:
• Sensor is ratiometric to supply voltage.
• Extended exposure to >
90% RH causes a reversible shift of
3% RH.
• Sensor is light sensitive. For best performance, shield sensor
from bright light.
Factory Calibration Data
HIH-4602-L-CP Sensors include a calibration and data
printout. See Table 2.
Table 2. Example Data Printout
Model HIH-4602-L-CP
Channel 92
Wafer 030996M
MRP 337313
Calculated values at 5 V
V
OUT
at 0% RH
V
OUT
at 75.3% RH
0.958 V
3.268 V
Linear output for 3.5% RH
accuracy at 25 °C
Zero offset
Slope
RH
0.958 V
30.680 mV/%RH
(V
OUT
- zero offset)/slope
(V
OUT
- 0.958)/0.0307
Ratiometric response for
0% RH to 100% RH
V
OUT
V
SUPPLY
(0.1915 to 0.8130)