4 Lead Strength
The crystal lead with the 0.9kg(9N) power (keep it for The crystal lead is not abnormity
(DIP)
30s±5s) and bend the crystal lead 90° with 0.45kg
power and two times
5 High Temperature
The crystal units shall be put in somewhere for 2 hrs Frequency Change: ±10ppm Max.
Endurance
at temperature of 85℃±2℃, then keep it for 1 to 2 hrs
Resistance Change:5kohm Max.
under room temperature.
6 Low Temperature
The crystal units shall be put in somewhere for 2 hrs
Endurance
at temperature of -25℃, then keep it for 1 to 2 hrs
under room temperature.
7 Humidity
The crystal units shall be put in somewhere at 40℃
Endurance
in relative humidity of 90-95% for 48 hrs, then keep
it for one or two hours under room temperature.
8 Temperature
Temperature shift from low(-40℃) to high(100℃, keep
Cycle
30 mins), satisfy high(100℃) to low(-40℃, keep
30 mins), then go up to room temperature for 5 cycles.
10 Salt Spray Test
Put the crystal units in the salt spray room (salt The appearance shall has no abnormity
density: 5%) at the temperature of 35℃ for 96 hrs.
and soldering is good.
Then clean it with water and dry its surface. Frequency Change: ±10ppm Max.
G2327002
VER. A
G2 Series 2.0x6.0mm Cylinder Through Hole Quartz Crystal
4-Feb-10
es
s
ance
ange:
o
m
ax.
E0-R-4-014 Rev. E Page 2