2900561

PHOENIX CONTACT Inc., USA Page 1 / 6
http://www.phoenixcon.com May 9, 2011
Extract from the online
catalog
ELR H5-ES-SC- 24DC/500AC-9
Order No.: 2900561
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900561
"3 in 1" hybrid motor starter for reversing 3~ AC motors up to 550
VAC, with 24 V DC input, 9 A output current, and emergency stop
function.
Commercial data
GTIN (EAN)
4 046356 527842
sales group G421
Pack 1 pcs.
Customs tariff 85364900
Product notes
WEEE/RoHS-compliant since:
02/09/2010
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Input data
Rated control supply voltage U
S
24 V DC
Rated control supply voltage range with reference
to U
S
0.8 ... 1.25
Rated control supply current I
S
35 mA
ELR H5-ES-SC- 24DC/500AC-9 Order No.: 2900561
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900561
PHOENIX CONTACT Inc., USA Page 2 / 6
http://www.phoenixcon.com May 9, 2011
Rated actuating voltage U
C
24 V DC
Rated actuating voltage range with reference to
U
C
0.8 ... 1.25
Rated actuating current I
C
3 mA
Switching threshold "0" signal, voltage 9.6 V
Switching threshold "1" signal voltage 19.2 V
Protective circuit Protection against polarity reversal Parallel polarity protection
diode
Surge protection
Typical response time < 35 ms
Typical turn-off time < 40 ms
Operating voltage display Green LED
Status display Yellow LED
Indication Red LED
Output data, load relay
Output name AC output
Nominal output voltage 500 V AC
Nominal output voltage range 48 V AC ... 550 V AC
Load current max. 9 A (see derating curve)
Leakage current 0 mA
Residual voltage < 0.3 V
Surge current 100 A (t = 10 ms)
Type of protection Surge protection
Output name Acknowledge output
Note Confirmation 01: Floating PDT contact
Nominal output voltage max. 253 V AC 0% ... 100% (300 V DC)
Continuous load current 2 A
Output data, signaling contact
Measuring via Current transformer for line current on L1 and L3
Connection data
Connection method Screw connection
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section stranded min. 0.14 mm²
Conductor cross section stranded max. 2.5 mm²
ELR H5-ES-SC- 24DC/500AC-9 Order No.: 2900561
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900561
PHOENIX CONTACT Inc., USA Page 3 / 6
http://www.phoenixcon.com May 9, 2011
Conductor cross section AWG/kcmil min. 26
Conductor cross section AWG/kcmil max 12
General data
Width 22.5 mm
Height 99 mm
Depth 114.5 mm
Test voltage input/output 4 kV
rms
Ambient temperature (operation) -25 °C ... 70 °C
Ambient temperature (storage/transport) -25 °C ... 70 °C
Mounting position Vertical (horizontal DIN rail)
Assembly instructions Can be aligned with spacing = 20 mm
Operating mode 100% operating factor
Degree of protection IP20
Name Standards/regulations
Standards/regulations DIN EN 50178
EN 60947
Name Power station requirements
Standards/regulations DWR 1300 / ZXX01/DD/7080.8d
Name Air and creepage distances between the power circuits
Standards/regulations DIN EN 50178
Rated surge voltage / insulation 6 kV/safe isolation
Rated insulation voltage 500 V
Pollution degree 2
Surge voltage category III
Safety integrity level according to IEC 61508-1 SIL 3 (safe shutdown)
Category as per ISO 13849-1 3
Performance Level as per ISO 13849-1 e
Category in acc. with EN 954-1 3
Certificates / Approvals
Certification CB, CUL Listed, UL Listed