mlcc_reli-R4
mlcc_reli_e-01
■ RELIABILITY DATA
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
16. Humidity Loading
Specified
Value
Temperatur
e Compensating
(Class 1
)
Standard
Appearance: No abnormality
Capacitance change: W
ithin ±7.5% or ±0.75pF, whichever is lar
ger.
Q: C<30pF:Q≧100+10C/3
C≧30pF:Q≧200 (C:Nominal capacitance
)
Insulation resistance: 500 MΩ min.
High Fr
equency Type
Appearance: No abnormality
Capacitance change:
C≦2
pF:Within ±0.4 pF
C>2pF:Within ±0.75 pF (C:Nominal capacitance
)
Insulation resistance: 500 MΩ min.
High Permittivity (Class 2)
Note 1
Appearance: No abnormality
Capacitance change: Within ±12.5% (BJ, B7, C6, C7
)
Within ±30%(F
)
Dissipation factor: 5.0% max. (BJ, B7, C6, C7)
11.0% max.(
F)
Insulation re
sistance: 25 MΩ
μF or 500 MΩ, whichever is smaller.
【Test Methods and Remarks】
Class 1
Standard High Frequency Type
Preconditioning None
Temperature 40±2℃ 60±2℃
Humidity 90 to 95%RH
Duration 500+24/ー0 hrs
Applied voltage Rated voltage
Charge/discharge current 50mA max.
Recovery 6 to 24 hrs (Standard condition) Note 5
Class 2
All items
Preconditioning Voltage treatment
(Rated voltage are applied for 1 hour at 40℃) Note 3
Temperature 40±2℃
Humidity 90 to 95%RH
Duration 500+24/ー0 hrs
Applied voltage Rated voltage
Charge/discharge current 50mA max.
Recovery 24±2 hrs (Standard condition) Note 5
17. High Temperature Loading
Specified
Value
Temperatur
e Compensating
(Class 1
)
Standard
Appearance: No abnormality
Capacitance change: Within ±3
% or ±0.3pF, whichever is lar
ger.
Q: C<10pF: Q≧200+10C
10≦C<30pF: Q≧275+2.5C
C≧30pF: Q≧350 (C:Nominal capacitance
)
Insulation resistance: 1000 MΩ min.
High Frequency T
ype
Appearance: No abnormality
Capacitance change:
Within ±3% or ±0.3pF, whichever is larger.
Insulation resistance: 1000 MΩ min.
High Permittivity (Class 2)
Note 1
Appearance: No abnormality
Capacitance change: Within ±12.5%(BJ, B7, C6, C7
)
Within ±30%(F
)
Dissipation factor: 5.0% max.(BJ, B7, C6, C7
)
11.0% max.(F
)
Insulation resistance: 50 MΩ
μF or 1000 MΩ, whichever is smaller.
【Test Methods and Remarks】
Class 1
Standard High Frequency Type
Preconditioning None
Temperature 125±3℃
Duration 1000+48/ー0 hrs
Applied voltage Rated voltage×2
Charge/discharge current 50mA max.
Recovery 6 to 24hr (Standard condition) Note 5
Class 2
BJ, F C6 B7, C7
Preconditioning Voltage treatment (Twice the rated voltage shall be
applied for 1 hour at 85℃, 105℃ or 125℃) Note 3, 4
Temperature 85±2℃ 105±3℃ 125±3℃
Duration 1000+48/ー0 hrs
Applied voltage Rated voltage×2 Note 4
Charge/discharge current 50mA max.
Recovery 24±2 hrs (Standard condition) Note 5
Note 1 The figures indicate typical specifications. Please refer to individual specifications in detail.
Note 2 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150+0/-10℃ for an hour and kept at room temperatur
e for 24±2hours.
Note 3 Voltage treatment :
Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in the test conditions, and
kept at room temperature for 24±2hours.
Note 4 150% of rated voltage is applicable to some items. Please r
efer to their specifications for further information.
Note 5 Standar
d condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressur
e: 86 to 106kPa
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following condi-
tion.
Te
mperatur
e: 20±2℃, Relative humidity: 60 to 70 % RH, Air pr
essure: 86 to 106kPa
Unless otherwise specified, all the tests are conducted under the "standard condition".