MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
SPECIFICATION
60W Single Output MoistureproofAdaptor
OWA-60U series
File Name:OWA-60U-SPEC 2017-08-07
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.4
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY
(Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load
10ms at full load 115VAC / 230VAC
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
1.2A / 115VAC 0.7A / 230VAC
<0.25mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-35 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
292.8K hrs min. MIL-HDBK-217F (25 )℃
130*53*35mm
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel
capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
PROTECTION
Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
COLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VAC
14 ~ 16V 17.5 ~ 23V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 50V 46 ~ 54V 53 ~ 62V 58 ~ 66V
87% 88% 88% 88.5% 88.5% 88.5% 88.5% 88.5% 89%
±4.0% ±4.0% ±4.0% ±3.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±1.5% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
12V 15V 20V 24V 30V 36V 42V 48V 54V
OWA-60U-12 OWA-60U-15 OWA-60U-20 OWA-60U-24 OWA-60U-30 OWA-60U-36 OWA-60U-42 OWA-60U-48 OWA-60U-54
150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p
5A 4A 3A 2.5A 2A 1.67A 1.5A 1.25A 1.12A
60W 60W 60W 60W 60W 60.12W 63W 60W 60.48W
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY STANDARDS
EMC EMISSION
UL8750 listed; CSA C22.2 No.250.13-12(except for 42V,48V,54V); IP67 approved for power body
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to FCC Part15
μ
CONSTANT CURRENT REGION
7.5 ~ 15V6 ~ 12V 10 ~ 20V 12 ~ 24V 15 ~ 30V
18 ~ 36V
24 ~ 48V 27 ~ 54V
21 ~ 42V
115VAC
230VAC
88% 89% 89% 90% 90% 90% 90% 91% 91%
COLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VAC
μ
0.41Kg; 16pcs/9.5Kg/0.85CUFT