External Components
Decoupling Capacitor
As with any high-performance mixed-signal IC, the
ICS512 must be isolated from system power supply
noise to perform optimally.
A decoupling capacitor of 0.01µF must be connected
between VDD and GND. It must be connected close to
the ICS512 to minimize lead inductance. No external
power supply filtering is required for the ICS512.
Series Termination Resistor
A 33Ω terminating resistor can be used next to the CLK
pin. The total on-chip capacitance is approximately 12
pF. A parallel resonant, fundamental mode crystal
should be used.
Crystal Load Capacitors
The device crystal connections should include pads for
small capacitors from X1 to ground and from X2 to
ground. These capacitors are used to adjust the stray
capacitance of the board to match the nominally
required crystal load capacitance. Because load
capacitance can only be increased in this trimming
process, it is important to keep stray capacitance to a
minimum by using very short PCB traces (and no vias)
between the crystal and device. Crystal capacitors, if
needed, must be connected from each of the pins X1
and X2 to ground.
The value (in pF) of these crystal caps should equal (C
L
-12 pF)*2. In this equation, C
L
= crystal load capacitance
in pF. Example: For a crystal with a 16 pF load
capacitance, each crystal capacitor would be 8 pF
[(16-12) x 2] = 8.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS512. These ratings, which
are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the
device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Recommended Operation Conditions
Item Rating
Supply Voltage, VDD 7 V
All Inputs and Outputs -0.5 V to VDD+0.5 V
Ambient Operating Temperature (commercial) 0 to +70° C
Ambient Operating Temperature (industrial) -40 to +85° C
Storage Temperature -65 to +150° C
Soldering Temperature 260° C
Parameter Min. Typ. Max. Units
Ambient Operating Temperature (commercial) 0 +70 ° C
Ambient Operating Temperature (industrial) -40 +85 ° C
Power Supply Voltage (measured in respect to GND) +3.0 +5.0 V