Tyco Electronics Power Systems 10
Data Sheet
August 22, 2006
36 Vdc to 75 Vdc Input; 1.2 Vdc to 5.0 Vdc Output; 10 A to 20 A
QW010/015/020 Series Power Modules: dc-dc Converters;
Characteristic Curves
The following figures provide typical characteristics curves for the QW015A0F1(VO = 3.3 V) module at room temperature (TA
= 25 °C)
Figure 25. Input Voltage and Current Characteristics.
Figure 26. Converter Efficiency vs. Output Current.
Figure 27. Output Ripple Voltage (IO = IO, max).
Figure 28. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 29. Transient Response to Step Increase in
Load from 50% to 75% of Full Load
(VI = 48 Vdc).
Figure 30. Start-up from Remote On/Off (IO = IO, max).
30 40 50 60 70
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0
I
O
= 15 A
I
O
= 7.5 A
I
O
= 1 A
INPUT VOLTAGE, V
I
(V)
INPUT CURRENT, I
I
(A)
012345678910111213141
5
OUTPUT CURRENT, I
O
(A)
95
90
85
80
75
70
EFFICIENCY, (%)
V
I
= 36 V
V
I
= 48 V
V
I
= 75 V
TIME,t (2 µs/div)
OUTPUT VOLTAGE,
V
O
(V) (10 mV/div)
TIME, t (100 µs/div)
OUTPUT VOLTAG
E,
V
O
(V) (200 mV/div)
OUTPUT CURRENT,
I
O
(A) (2 A/div)
TIME, t (100 µs/div)
OUTPUT VOLTAG
E,
V
O
(V) (200 mV/div)
OUTPUT CURRENT,
I
O
(A) (2 A/div)
TIME, t (100 µs/div)
OUTPUT VOLTAG
E,
V
O
(V) (200 mV/div)
OUTPUT CURRENT,
I
O
(A) (2 A/div)
Tyco Electronics Power Systems 11
Data Sheet
August 22, 2006
36 Vdc to 75 Vdc Input; 1.2 Vdc to 5.0 Vdc Output; 10 A to 20 A
QW010/015/020 Series Power Modules: dc-dc Converters;
Characteristic Curves
The following figures provide typical characteristics curves for the QW010A0A1(VO = 5.0 V) module at room temperature (TA =
25 °C)
Figure 31. Input Voltage and Current Characteristics.
Figure 32. Converter Efficiency vs. Output Current.
Figure 33. Output Ripple Voltage (IO = IO, max).
Figure 34. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 35. Transient Response to Step Increase in Load
from 50% to 75% of Full Load
(VI = 48 Vdc).
Figure 36. Start-up from Remote On/Off (IO = IO, max).
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
30 35 40 45 50 55 60 65 70 7
5
INPUT VOLTAGE, V
I
(V)
INPUT CURRENT, I
I
(A)
I
O
= 10A
I
O
= 5A
I
O
= 0A
70
75
80
85
90
95
01234567891
0
OUTPUT CURRENT, I
O
(A)
EFFICIENCY, (%)
V
I
= 36V
V
I
= 48V
V
I
= 75V
TIME, t (1 µs/div)
OUTPUT VOLTAG
E,
V
O
(V) (10 mV/div)
TIME, t (100 µs/div)
OUTPUT VOLTAG
E,
V
O
(V) (200 mV/div)
OUTPUT CURRENT,
I
O
(A) (2 A/div)
TIME, t (100 µs/div)
OUTPUT VOLTAG
E,
V
O
(V) (200 mV/div)
OUTPUT CURRENT,
I
O
(A) (2 A/div)
TIME, t (10 ms/div)
OUTPUT VOLTAG
E,
V
O
(V) (2 V/div)
REMOTE ON/OFF,
V
ON/OFF
(5 V/div)
Tyco Electronics Power Systems 12
Data Sheet
August 22, 2006
36 Vdc to 75 Vdc Input; 1.2 Vdc to 5.0 Vdc Output; 10 A to 20 A
QW010/015/020 Series Power Modules: dc-dc Converters;
Test Configurations
Note: Measure input reflected ripple current with a simulated source
inductance (L
TEST) of 12µH. Capacitor CS offsets possible
battery impedance. Measure current as shown above.
Figure 37. Input Reflected Ripple Current Test Setup.
Note: Scope measurements should be made using a BNC socket,
with a 10 µF tantalum capacitor and a 1 µF ceramic capcitor.
Position the load between 51 mm and 76 mm (2 in and 3 in)
from the module
Figure 38. Peak-to-Peak Output Ripple Measurement
Test Setup.
Note: All voltage measurements to be taken at the module termi-
nals, as shown above. If sockets are used then Kelvin con-
nections are required at the module terminals to avoid
measurement
errors due to socket contact resistance.
Figure 39. Output Voltage and Efficiency Test Setup.
Safety Considerations
For safety-agency approval of the system in which the power
module is used, the power module must be installed in com-
pliance with the spacing and separation requirements of the
end-use safety agency standard, i.e., UL60950, CSA C22.2
No. 60950-00, and
VDE 0805:2001-12 (IEC60950, 3rd Ed).
These converters have been evaluated to the spacing
requirements for Basic Insulation, per the above safety stan-
dards.
For Basic Insulation models ("–B" Suffix), 1500 Vdc is
applied from VI to VO to 100% of outgoing production.
For end products connected to –48 Vdc, or –60 Vdc nomianl
DC MAINS (i.e. central office dc battery plant), no further
fault testing is required.
Note:–60 V dc nominal bettery plants are not available in the
U.S. or Canada.
For all input voltages, other than DC MAINS, where the input
voltage is less than 60 Vdc, if the input meets all of the
requirements for SELV, then:
n
The output may be considered SELV. Output voltages will
remain withing SELV limits even with internally-generated
non-SELV voltages. Single component failure and fault
tests were performed in the power converters.
n
One pole of the input and one pole of the output are to be
grounded, or both circuits are to be kept floating, to main-
tain the output voltage to ground voltage within ELV or
SELV limits.
For all input sources, other than DC MAINS, where the input
voltage is between 60 and 75 Vdc (Classified as TNV-2 in
Europe), the following must be adhered to, if the converter’s
output is to be evaluated for SELV:
n
The input source is to be provided with reinforced insula-
tion from any hazardous voltage, including the AC mains.
n
One VI pin and one VO pin are to be reliably earthed, or
both the input and output pins are to be kept floating.
n
Another SELV reliability test is conducted on the whole
system, as required by the safety agencies, on the combi-
nation of supply source and the subject module to verify
that under a single fault, hazardous voltages do not
appear at the module’s output.
The power module has ELV (extra-low voltage) outputs
when all inputs are ELV.
All flammable materials used in the manufacturing of these
modules are rated 94V-0, and UL60950A.2 for reduced
thicknesses. The input to these units is to be provided with a
maximum 5A time-delay in the unearthed lead.
TO OSCILLOSCOPE
12 µH
C
S
220 µF
ESR < 0.1
@ 20 ˚C, 100 kHz
V
I
(+)
V
I
(-)
B
ATTERY
L
TEST
33 µF
ESR < 0.7
@ 100 kHz
V
O
(+)
V
O
(–)
10 µF
RESISTIVE
LOAD
SCOPE
COPPER STRIP
1 µF
V
I
(+)
I
I
I
O
SUPPLY
CONTACT
RESISTANCE
CONTACT AND
DISTRIBUTION LOSSES
LOAD
SENSE(+)
V
I
(-)
V
O
(+)
V
O
(-)
SENSE(-)
η
V
O(+)
V
O(-)
[]I
O
×
V
I(+)
V
I(-)
[]I
I
×
------------------------------------------------
⎝⎠
⎛⎞
100×=

QW020A0P1