ESE-13H05D

Detector Switches/ESE13
1 2 3 4 5 6 7 8 9
Product Code
Design No
6th
H
V
From under to top type
From top to under type
Type
Without Boss
With Boss
Without Boss
With Boss
Positioning
J-bent Type
J-bent Type
Straight Type
Straight Type
Terminal Type
9th
A
B
C
D
gnitaR
m 005ecnatsiseR tcatnoC Ω max. (Initial)
M 001ecnatsiseR noitalusnI Ω min. (100 V DC)
egatloV gnidnatshtiW cirtceleiD
.xam Nm 003ecroF gnitarepO
mm 2.1thgieH gnitnuoM
worht-1 elop-1sworhT dna seloP
Full Travel (Pushing distance)
Type V : 2.15 mm (2.15 mm)
Type H : 3.05 mm (2.15 mm)
.nim selcyc 0000,5efiL gnitarepO
C° 06+ ot C° 01egnaR erutarepmeT
sruoh 69 rof C° 07+ecnatsiseR taeH
sruoh 69 rof C° 52ecnatsiseR erutarepmeT
woL
sruoh 69 rof HR % 59 ot % 09 C° 04+ecnatsiseR ytidimuH
Minimum Quantity/Packing Unit
)kcaP leeR( gnipaT dessobmE .scp 00,0
5H31ESE
)kcaP leeR( gnipaT dessobmE .scp 00,03V31ESE
Quantity/Carton
.scp 00,003H31ESE
.scp 0008,1V31ESE
1VL Detector Switches
Type:
ESE13
Features
Thin type : Height=1.2 mm
Highly reliable contact
SMD type (Embossed taping, Refl ow soldering)
Explanation of Part Numbers
Recommended Applications
Detection of media in portable electronic equipment
(Mobile phones / Digital still cameras / Camcorders)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
ANCTB48E 201701-Fd
Panasonic Corporation 2017
–1–
industrial.panasonic.com/ac/e/
2017.01
50 μA 3 V DC to 10 mA 5 V DC (Resistive load)
100 V AC for 1 minute
ANCTB.indb 23 17/01/23 18:15
Detector Switches/ESE13
A
c
t
i
o
n
d
i
r
e
c
t
i
o
n
Release position
Separate
terminal
Common
terminal
Separate
terminal
Common
terminal
ON angular dimension
Pivot center
ON start
position
(1)
D
C
B
A
1.2
4.2
3.6
1.95
1.14±0.3
1.55±0.35
(0.58)
3.05±0.3
1.2±0.2
2.65±0.3
0.5
2±0.05
3.0
0.5
1.0
0.4
(15˚)
(60˚)
0.2 max.
0.9
0.5
0.6
0.55
0.65
0.45
0.5
-0.1
0
φ
0.6
4.2
0.7
4.6
2.2
A
C
B
D
3.0 0.55
4.3
1.0
2.0
0.7
-0
+0.1
A
c
t
i
o
n
d
i
r
e
c
t
i
o
n
Release position
Separate
terminal
Common
terminal
Pivot center
Separate
terminal
Common
terminal
ON angular dimension
ON start
position
(1)
A
B
C
D
4.2
3.6
1.95
1.2
1.14±0.3
1.55±0.35
3.05±0.3
2.65±0.3
1.2±0.2
0.5
(0.58)
1.0
0.55
2±0.05
3.0
0.5
0.5
0.2 max.
0.9
0.6
(15 ˚)
(60 ˚)
0.4
0.65
0.45
0.5
0.5
-0.1
0
φ0.6
D
C
B
A
0.7
2.2
3.0 0.55
4.3
2-
φ
0.8
-0
+0.1
1.02.0
0.7
D
C
B
A
1.2
4.2
3.6
2.3
0.2 max.
0.77±0.3
2.14±0.35
(15 °)
(60 °)
0.4
0.55
(0.38)
1.0
(0.58)
3.0
0.5
0.5
2±0.05
1.2±0.2
1.6±0.3
3.05±0.3
0
–0.1
φ0.6
0.45
0.65
0.65
0.6
0.5
0.5
A
B
C
D
2.0 1.0
2.2
0.7 0.7
4.3
0.553.0
+0.1
0
2-
φ
0.8
Full travel
Separate
terminal
Common
terminal
Separate
terminal
Common
terminal
ON angular
dimension
Pivot center
ON start
position
No. 1
With boss
ESE13V01B
Without boss
ESE13V01A
ESE13V Straight ter mi nals
1-pole 1-throw
ESE13V J-bent terminals
1-pole 1-throw
ESE13H J-bent terminals
1-pole 1-throw
No. 2
With boss
ESE13V01D
Without boss
ESE13V01C
No. 3
With boss
ESE13H01B
Without boss
ESE13H01A
Dimensions in mm (not to scale)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
ANCTB48E 201701-Fd
Panasonic Corporation 2017
industrial.panasonic.com/ac/e/
Panasonic Corporation
Electromechanical Control Business Division
–2–
2-
φ
0.8
ANCTB.indb 24 17/01/23 18:15
Detector Switches/ESE13
Full travel
Separate
terminal
Common
terminal
Separate
terminal
Common
terminal
Pivot center
ON start
position
ON angular
dimension
0.77±0.3
(2.14±0.35)
3.05±0.3
1.6±0.3
1.2±0.2
0.5
(0.38)
2±0.05
0.5
0.4
0.55
3.0
1.0
(0.58)
0.2 max.
(15 ˚)
(60 ˚)
0.6
0.7 0.7
2.0
4.6
2.2
3 0.55
4.3
2-
φ
0.8
+0.1
-0
3.6
4.2
1.2
2.3
0.6
0.65
A
B
C
D
D
C
B
A
-0.1
0
φ0.6
0.5
0.65
φ380.0±2.0
16.4
Packed portion
Non-packed portion
(100 mm min.)
Non-packed portion
(160 mm min.)
Cover tape
Carrier tape
POTDNE
Drawing direction
Pilot holes
Leading portion 400 mm min
16.0±0.3
1.75±0.1
7.5±0.1
P=8.0±0.1
4.0±0.1
2.0±0.1
φ
1.5
+0.1
0
13.5
Common
terminal
C
Circuit Diagram
Standard Reel Dimensions in mm (not to scale)
No. 4
With boss
ESE13H01D
Without boss
ESE13H01C
Dimensions in mm (not to scale)
gnipaT reirraC dessobmEleeR gnipaT
ESE13H Straight terminals
1-pole 1-throw
1-pole 1-throw (N.O)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
ANCTB48E 201701-Fd
Panasonic Corporation 2017
industrial.panasonic.com/ac/e/
Panasonic Corporation
Electromechanical Control Business Division
–3–
ANCTB.indb 25 17/01/23 18:15

ESE-13H05D

Mfr. #:
Manufacturer:
Panasonic
Description:
Detector Switches SWITCH TACTILE
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS