1
Non resettable fuses
MSB
www.schurter.com /PG01_2
Fuses
Surface Mount Fuse, 7 x 2 mm, Time-Lag T, 125 VAC, 125 VDC
IEC 60127-4 · 125 VAC · 125 VDC · Time-Lag T
Description
- Low Breaking Capacity
- Directly solderable on printed circuit boards
Standards
- IEC 60127-4/2
- UL 248-14
- CSA C22.2 no. 248.14
Approvals
- UL File Number: E42088
Applications
- Telecom
- Household appliances
References
Packaging Details
Square Footprint Type MKT
Corresponding Fuseholder 231786; 231787
Weblinks
pdf datasheet, html-datasheet, General Product Information, Packaging
details, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS,
REACH, Distributor-Stock-Check, Detailed request for product
Technical Data
Rated Voltage 63 - 125 VAC, 65 - 125 VDC
Rated current 0.75 - 15 A
Breaking Capacity 50 A - 150 A
Characteristic Time-Lag T
Mounting PCB,SMT
Admissible Ambient Air Temp. -55 °C to 85 °C
Climatic Category 55/085/56 acc. to IEC 60068-1
Material: Tube Ceramic
Material: Endcaps Tin-Plated Copper Alloy
Unit Weight 0.07 g
Storage Conditions 0 °C to 60 °C, max. 70% r.h.
Product Marking , Rated current
Soldering Methods Reflow, Wave
Soldering Profile
Solderability 235 °C / 2 sec acc. to IEC 60068-2-58,
Test Td,Fig. 2B (Reflow) // 245 °C / 3
sec (Wave)
Resistance to Soldering Heat 260 °C / 10 sec acc. to IEC 60068-2-58,
Test Td
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
General Product Information
Dimension
7 mm
ø 2
7
±0.3
2
±0.2
±0.1
4 2.7
3.1
Soldering pads