Enhanced Product ADG1212-EP
Rev. A | Page 5 of 12
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 3.
Parameter Rating
V
to V
35 V
V
to GND −0.3 V to +25 V
V
to GND +0.3 V to −25 V
Analog Inputs
1
V
SS
− 0.3 V to V
DD
+ 0.3 V
or 30 mA, whichever
occurs first
V
DD
+ 0.3 V or 30 mA,
whichever occurs first
Peak Current, S or D 100 mA (pulsed at
1 ms, 10% duty cycle
maximum)
Continuous Current per Channel, S or D 25 mA
Operating Temperature Range −55°C to +125°C
Storage Temperature Range −65°C to +150°C
Junction Temperature 150°C
16-Lead TSSOP, θ
JA
Thermal
Impedance (4-Layer Board)
112°C/W
Lead Temperature, Soldering As per JEDEC J-STD-020
1
Overvoltages at IN, S, or D are clamped by internal diodes. Current should be
limited to the maximum ratings given.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational section of
this specification is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Only one absolute maximum rating may be applied at any
one time.
Table 4. ADG1212-EP Truth Table
ADG1212-EP INx Switch Condition
0 Off
ESD CAUTION