DS1626/DS1726
4 of 12
EEPROM AC ELECTRICAL CHARACTERISTICS
(V
DD
= 2.7V to 5.5V, T
A
= -55°C to +125°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
EEPROM Write Cycle Time t
wr
4 10 ms
EEPROM Writes N
EEWR
-55°C to +55°C 50k Writes
EEPROM Data Retention t
EEDR
-55°C to +55°C 10 Years
AC ELECTRICAL CHARACTERISTICS
(V
DD
= 2.7V to 5.5V, T
A
= -55°C to +125°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
9 bits 93.75
10 bits 187.5
11 bits 375
Temperature Conversion Time t
TC
12 bits 750
ms
Data In to Clock Setup t
DC
(Note 5) 35 ns
Clock to Data In Hold t
CDH
(Note 5) 40 ns
Clock to Data Out Delay t
CDD
(Notes 5, 6) 150 ns
Clock Low/High Time t
CL
, t
CH
(Note 5) 285 ns
Clock Frequency f
CLK
(Note 5) 0 1.75 MHz
Clock Rise/Fall Time t
R
, t
F
(Note 5) 500 ns
RST to Clock Setup
t
RC
(Note 5) 100 ns
Clock to RST Hold
t
CRH
(Note 5) 40 ns
RST Inactive Time
t
RI
(Note 7) 125 ns
Clock High to I/O Hi-Z t
CDZ
(Note 5) 50 ns
RST Low to I/O Hi-Z
t
RDZ
(Note 5) 50 ns
CNV Pulse Width
t
CNV
(Note 8) 250ns 500ms
I/O Capacitance C
I/O
10 pF
Input Capacitance C
I
5 pF
NOTES:
1) All voltages are referenced to ground.
2) See Figure 2 for TYPICAL OPERATING CURVES.
3) I
STBY
, I
DD
specified with DQ, CLK/CNV = V
DD
and RST = GND.
4) Drift data is based on a 1000hr stress test at +125°C with V
DD
= 5.5V.
5) See Timing Diagrams in Figure 3. All timing is referenced to 0.7 x V
DD
and 0.3 x V
DD
.
6) Load capacitance = 50pF.
7) t
RI
must be 10ms minimum following any write command that involves the E
2
memory.
8) 250ns is the guaranteed minimum pulse width for a conversion to start, however, a smaller pulse
width may start a conversion.
DS1626/DS1726
5 of 12
Figure 2. TYPICAL OPERATING CURVES
Figure 3. TIMING DIAGRAMS
a) Read Timing
b) Write Timing
-1
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
0 10203040506070
REFERENCE TEMPERATURE (°C)
ERROR °C
-1
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
-10 0 10 20 30 40 50 60 70 80
REFERENCE TEMPERATURE (°C)
ERROR (°C)
+3σ
+3σ
-3σ
-3σ
MEAN
MEAN
DS1626
DS1726
t
RC
t
CRH
t
CRH
t
RC
t
RI
DS1626/DS1726
6 of 12
OPERATION—MEASURING TEMPERATURE
The DS1626/DS1726 measure temperature using a bandgap-based temperature sensor. A delta-sigma
analog-to-digital converter (ADC) converts the measured temperature to a digital value that is calibrated
in degrees Celsius; for Fahrenheit applications a lookup table or conversion routine must be used.
Communication with the DS1626/DS1726 is achieved through a 3-wire serial interface, and all data is
transmitted LSb first.
The DS1626/DS1726 can be programmed to take continuous temperature measurements (continuous
conversion mode) or to take single temperature measurements on command (one-shot mode). The
measurement mode is programmed by the 1SHOT bit in the configuration register as explained in the
CONFIGURATION REGISTER section of this data sheet. The 1SHOT bit is stored in EEPROM, so it can
be programmed prior to installation if desired. In continuous conversion mode, when a Start Convert T
command is issued the DS1626/DS1726 perform consecutive temperature measurements until a Stop
Convert T command is issued. In one-shot mode, the Start Convert T command causes one temperature
measurement to be taken and then the DS1626/DS1726 return to a low-power idle state.
The resolution of the DS1626/DS1726 digital temperature data is user-configurable to 9, 10, 11, or 12
bits, corresponding to temperature increments of 0.5°C, 0.25°C, 0.125°C, and 0.0625°C, respectively.
The resolution is set by the EEPROM R0 and R1 bits in the configuration register. Note that the
conversion time doubles for each additional bit of resolution.
After each temperature measurement and analog-to-digital conversion, the DS1626/DS1726 store the
measured temperature as a two’s complement number in the 12-bit temperature register (see Figure 4).
The sign bit (S) indicates if the temperature is positive or negative: for positive numbers S = 0 and for
negative numbers S = 1. The Read Temperature command provides user access to the temperature
register.
When the DS1626/DS1726 are configured for 12-bit resolution, all 12 bits of the temperature register will
contain temperature data. For 11-bit resolution, the 11 MSbs (bits 11 through 1) of the temperature
register will contain data and bit 0 will read out as 0. Likewise, for 10-bit resolution, the 10 MSbs (bits 11
through 2) will contain data, and for 9-bit the 9 MSbs (bits 11 through 3) will contain data, and all unused
LSbs will contain 0s. Since the DS1626/DS1726 transmit data LSb first, when reading data from the
temperature register, all 12 bits must be read in order to receive all MSbs of the measured data, regardless
of the conversion resolution. Table 2 gives examples of 12-bit resolution digital output data and the
corresponding temperatures.
Figure 4. TEMPERATURE, T
H
, and T
L
REGISTER FORMAT
BIT 11 BIT 10 BIT 9 BIT 8 BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
S 2
6
2
5
2
4
2
3
2
2
2
1
2
0
2
-1
2
-2
2
-3
2
-4