Pressure reference Gauge Absolute
0 ~ 100 0 ~ 350 0 ~ 1000 0 ~ − 100 − 100 ~ 300 0 ~100
kPa
Rated pressure range
R2 (R 1/4)
GF (G 3/8)
G2 (G 1/4)
■
LIST OF MODEL NUMBERS
PA-858-102G-R2 PA-858-352G-R2 PA-858-103G-R2 PA-858-102V-R2 PA-858-302R-R2 PA-858-102A-R2
PA-858-102A-GFPA-858-102G-GF PA-858-352G-GF PA-858-103G-GF PA-858-102V-GF PA-858-302R-GF
PA-858-102G-G2 PA-858-352G-G2 PA-858-103G-G2 PA-858-102V-G2 PA-858-302R-G2 PA-858-102A-G2
Fitting
PA-858
PRESSURE TRANSDUCERS WITH AMP.
General specifications
■
STANDARD SPECIFICATIONS
Item
Pressure reference
Rated pressure range
Maximum pressure
Break-down pressure
Operating temp. range
Compensated temp. range
Storage temp.
Operating humidity
Pressure medium
Insulation resistance
Dielectric strength
Sealed liquid
Pressure port
Net weight
Protection grade
Model
number
PA-858
102G 352G 103G 102V 302R 102A
Gauge Absolute
100 350 1000 − 100 − 100 ~ 300 100 (abs)
200 700 2000 200 600 200 (abs)
300 1050 3000 300 900 300 (abs)
Corrosive gases/liquids compatible with SUS 316L
R2 : Approx. 165, GF : Approx. 180, G2 : Approx. 170
IP65
100 (500 V DC)
500 V AC, 60 s
(
Leakage current 1 mA maximum
)
Silicone oil
R 1/4
、
G 3/8
(
Flash diaphragm
)、
G 1/4
※1
※1
: An “O” ring provided. (G 3/8 : P18, G 1/4 : P15)
0 ~ 50
35 ~ 85
(
No condensation
)
− 20 ~ 80
(
Atmospheric pressure, humidity 65 %RH maximum
)
− 20 ~ 70
kPa
kPa
kPa
°C
°C
%RH
°C
M
minimum
g
OUnless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC, load resistance of 250 Ω.
Power
Supply voltage 24 ± 10 %
(
Including ripple percentage
)
V DC
※ Verify the above model numbers when placing orders.