PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) below 100mΩ continuous, automatic revovery
Over Load Protection (OLP) 150% load, continuous, autmatic recovery
Isolation Voltage
(5)
I/P to O/P
tested for 1 second
rated for 1 minute
2kVDC
1.6kVDC
Isolation Capacitance 110pF max.
Isolation Resistance 1GΩ typ.
Isolation Grade Functional
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range
(6)
without derating (see graph) -40°C to +75°C
Maximum Case Temperature +105°C
Temperature Coefficient ±0.02%/°C
Operating Humidity non-condensing 5% - 95% RH max.
Vibration MIL-STD-202G
MTBF according to MIL-HDBK-217F, G.B. +25°C 1776 x 10
3
hours
SAFETY AND CERTIFICATIONS
Certificate Type Report / File Number Standard
Information Technology Equipment, General Requirements for Safety (LVD) L0339m26-B1-L EN60950-1, 2nd Endition AM2 , 2013
Audio/video, information and communication technology equipment - Safety requirements
L0339m27-B1-L ICE/EN62368-1, 2014
RoHS2 RoHS-2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement
with external filter
(see filter suggestions)
EN55022, Class A
EN55022, Class B
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN55024, 2010
continued on next page
DC/DC Converter
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
RS6
Series
ECO-5
REV.: 4/2017www.recom-power.com
100
80
70
60
40
20
0
-40 0 604020-20 100
8575
12080
Ambient Temperature [°C]
Safe Operating Area
Notes:
Note6: Derating Graph is referring to RS6-0505S. For more details, please contact our technical support service at TechsupportAT@recom-power.com.
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Derating Graph
(@ Chamber and natural convection 0.1m/s)