1
Power entry modules without line filter
DD11
www.schurter.com /PG05
Connectors
IEC Appliance Inlet C14 with Line Switch 2-pole, Fuseholder 1- or 2-pole
Order required accessories separately
Standard or Medical Fuse drawer
C14
70° C
Description
- Panel Mount :
Screw-on version from front or rear side
- 3 Functions :
Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for
fuse-links 5 x 20 mm 1- or 2-pole
- V-Lock notch standard
- Quick connect terminals 4.8 x 0.8 mm
Approvals
- VDE Certificate Number: 40018283
- UL File Number: E93617
Characteristics
- Ultra-compact design. Ideal for low profile designs
- All single elements are already wired
- Fuse drawer meets requirements of medical standard IEC/EN 60601-1
- Ideal for application with high transient loads
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
- Solder terminals
- Fuse drawer 1-pole, plus spare fuse case
- Fuse drawer 2-pole, with shorting bar
- Other rocker marking
- Line switch 1-pole
- Protection class II, 70°C
References
Alternative: version with line filter DD12
Alternative: version for snap-in mounting KM
Alternative: version for PCB mounting DD21
Weblinks
pdf datasheet, html-datasheet, General Product Information, RoHS,
CHINA-RoHS, REACH, Distributor-Stock-Check, Accessories, Detailed
request for product
Technical Data
Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 8 A / 250 VAC; 60 Hz ¹⁾
Dielectric Strength > 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
Allowable Operation Tempe-
rature
-25 °C to 85 °C
IP-Protection from front side IP 40 acc. to IEC 60529
Insulation cover Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminals 4.8 x 0.8 mm
Panel Thickness s Screw-on mounting: max 8 mm
Mounting screw torque max 0.5 Nm
Rear side mounting: max 2 mm
Material: Housing Thermoplastic, black, UL 94V-0
appliance inlet/-outlet C14 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
Fuseholder 1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Rated Power Acceptance @
Ta 23 °C
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Power Acceptance @ Ta >
23°C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Line Switch Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical Details
1)
with cover 7 A, without cover 8 A
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
General Product Information