DCPT-6/2-45-SP

RW 2056 Revision 4
Page 4 of 10
Date Printed 3/3/2014
If this document is printed it becomes uncontrolled. Check latest revision in DMTEC /Intranet on the nearest PC
RW 2056 Revision 4
Page 5 of 10
Date Printed 3/3/2014
If this document is printed it becomes uncontrolled. Check latest revision in DMTEC /Intranet on the nearest PC
3.
TEST METHODS
3.1
Preparation of Test Specimens
Unless otherwise specified, tests shall be carried out on specimens of sleeving recovered by
conditioning in a fan assisted air circulating oven at 200 ± 5°C for 4 ± 1 minutes and allowed to
cool in air to ambient temperature. No pre-conditioning period is required prior to testing.
Unless otherwise specified, all tests shall be made under standard ambient conditions according
to IEC Publication 60212. In cases of dispute the tests shall be carried out at a temperature of
23 ± 2°C and at 50 ± 5% relative humidity.
3.2
Dimensions and Longitudinal Change
The test method shall be as specified in ASTM D2671.
The length and inside diameter of three 150mm long specimens of expanded sleeving shall be
measured. The specimens shall be recovered in a fan assisted air circulating oven and the length
and inside diameter of each shall be measured. The longitudinal change shall be expressed as a
percentage of the original length. The minimum and maximum recovered wall thickness shall
be determined.
3.3
Tensile Strength and Ultimate Elongation
The test method shall be as specified in ISO 37.
For sleeving of recovered bore greater than 6mm, five Type 2 dumb-bell specimens shall be
tested. For sleeving of recovered bore less than or equal to 6mm, five tubular specimens 125mm
long shall be tested. Initial jaw separation shall be 50 mm and rate of jaw separation shall be
100 ± 10mm per minute.
The test shall be carried out at a temperature of 23 ± 2°C.
3.4
Secant Modulus at 2% Strain
The test method shall be as specified in Method A of ASTM D882.
For sleeving of recovered bore greater than 6mm, five strip specimens 150mm long shall be
tested. For sleeving of recovered bore less than or equal to 6mm five tubular specimens 150mm
long shall be tested. Initial jaw separation shall be 100mm and rate of jaw separation 10 ± 1mm
per minute. The test shall be carried out at a temperature of 23 ± 2°C.
3.5
Specific Gravity
The test method shall be as specified in Method A of ISO 1183.
3.6
Heat Shock
The test method shall be as specified in ASTM D2671.
For sleeving of recovered bore 6mm or less, apply the test to cut lengths of that sleeving. For
sleeving of recovered bore greater than 6mm, apply the test to strips 6mm wide, cut from the
recovered sleeving, with their lengths parallel to the extruded axis. Mandrel diameter shall be
10x specimen thickness ± 10%. For tubular specimens the thickness is the outside diameter.
The specimens shall be conditioned as specified in Table 1.
RW 2056 Revision 4
Page 6 of 10
Date Printed 3/3/2014
If this document is printed it becomes uncontrolled. Check latest revision in DMTEC /Intranet on the nearest PC
TEST METHODS (Cont’d)
3.7
Heat Ageing
The test method shall be as specified in ISO 188.
Five tensile test specimens prepared as in Clause 3.3 shall be conditioned in a fan assisted air
circulating oven as specified in Table 1. After conditioning the specimens shall be removed
from the oven, allowed to cool naturally to room temperature and tested for Ultimate Elongation
according to clause 3.3.
3.8
Low Temperature Flexibility
The test method shall be as specified in Procedure C of ASTM D2671.
For sleeving of recovered bore 6mm or less, apply the test to whole sections of recovered
sleeving. For sleeving of recovered bore greater than 6mm, apply the test to strips 6mm wide,
cut from the recovered sleeving, with their lengths parallel to the extruded axis. Mandrel
diameter shall be 10 x specimen thickness ± 10%. For tubular specimens the thickness is the
outside diameter.
The specimens and mandrel shall be conditioned as specified in Table 1.
3.9
Flammability
The test method shall be as specified in ASTM D876.
The test shall be carried out on size 12/6.
3.10
Electric Strength
The test method shall be as specified in IEC 60243 (Short time test).
3.11
Copper Contact Corrosion
The test method shall be as specified in ASTM D2671.
The specimens shall be conditioned in a fan assisted air circulating oven as specified in
Table 1, allowed to cool naturally to room temperature and tested for Ultimate Elongation
according to Clause 3.3.
3.12
Copper Mirror Corrosion
The test method shall be as specified in ASTM D2671.
The specimens shall be conditioned as specified in Table 1.
3.13
Water Absorption
The test method shall be as specified in Method 1 of ISO 62.
For sleeving of recovered bore greater than 8mm, three disc specimens of diameter
25 ± 1mm shall be cut from the sleeving. For sleeving of recovered bore less than or equal to
8mm, three tubular specimens 50mm long shall be cut from the sleeving.