IDT1337AG
REAL-TIME CLOCK WITH I
2
C SERIAL INTERFACE RTC
IDT®
REAL-TIME CLOCK WITH I
2
C SERIAL INTERFACE 16
IDT1337AG REV C 011514
AC Electrical Characteristics
Unless stated otherwise, VCC = 1.8 V to 5.5 V, Ambient Temp. -40 to +85C, Note 1
Parameter Symbol Conditions Min. Typ. Max. Units
SCL Clock Frequency f
SCL
Fast Mode 100 400 kHz
Standard Mode 0 100
Bus Free Time Between a STOP and
START Condition
t
BUF
Fast Mode 1.3 µs
Standard Mode 4.7
Hold Time (Repeated) START
Condition, Note 10
t
HD:STA
Fast Mode 0.6 µs
Standard Mode 4.0
Low Period of SCL Clock t
LOW
Fast Mode 1.3 µs
Standard Mode 4.7
High Period of SCL Clock t
HIGH
Fast Mode 0.6 µs
Standard Mode 4.0
Setup Time for a Repeated START
Condition
t
SU:STA
Fast Mode 0.6 µs
Standard Mode 4.7
Data Hold Time, Notes 11, 12 t
HD:DAT
Fast Mode 0 0.9 µs
Standard Mode 0
Data Setup Time, Note 13 t
SU:DAT
Fast Mode 100 ns
Standard Mode 250
Rise Time of Both SDA and SCL
Signals, Note 14
t
R
Fast Mode 20 + 0.1C
B
300 ns
Standard Mode 1000
Fall Time of Both SDA and SCL Signals,
Note 14
t
F
Fast Mode 20 + 0.1C
B
300 ns
Standard Mode 300
Setup Time for STOP Condition t
SU:STO
Fast Mode 0.6 µs
Standard Mode 4.0
Capacitive Load for Each Bus Line,
Note 14
C
B
400 pF
I/O Capacitance (SDA, SCL) C
I/O
Note 15 10 pF
32.768 kHz Clock Accuracy with
External Crystal
T
A=25°C
V
CC=3.3 V
±10 ppm
32.768 kHz Clock Accuracy with
Internal Crystal
T
A=25°C
V
CC=3.3 V
(crystal accuracy
±20ppm)
±30 ppm
IDT1337AG
REAL-TIME CLOCK WITH I
2
C SERIAL INTERFACE RTC
IDT®
REAL-TIME CLOCK WITH I
2
C SERIAL INTERFACE 17
IDT1337AG REV C 011514
Note 1: Limits at -40°C are guaranteed by design and are not production tested.
Note 2: SCL only.
Note 3: SDA, INTA
, and SQW/INTB.
Note 4: I
CCA
—SCL clocking at maximum frequency = 400 kHz, VIL = 0.0V, VIH = VCC.
Note 5: Specified with the I
2
C bus inactive, VIL = 0.0V, VIH = VCC.
Note 6: SQW enabled.
Note 7: Specified with the SQW function disabled by setting INTCN = 1.
Note 8: Using recommended crystal on X1 and X2.
Note 9: The device is fully accessible when 1.8 <
VCC < 5.5 V. Time and date are maintained when 1.3 V < VCC <
1.8 V.
Note 10: After this period, the first clock pulse is generated.
Note 11: A device must internally provide a hold time of at least 300 ns for the SDA signal (referred to the V
IHMIN
of
the SCL signal) to bridge the undefined region of the falling edge of SCL.
Note 12: The maximum t
HD:DAT
need only be met if the device does not stretch the LOW period (t
LOW
) of the SCL
signal.
Note 13: A fast-mode device can be used in a standard-mode system, but the requirement t
SU:DAT
> to 250 ns must
then be met. This is automatically the case if the device does not stretch the LOW period of the SCL signal. If such
a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line t
R(MAX)
+
t
SU:DAT
= 1000 + 250 = 1250 ns before the SCL line is released.
Note 14: C
B
—total capacitance of one bus line in pF.
Note 15: Guaranteed by design. Not production tested.
IDT1337AG
REAL-TIME CLOCK WITH I
2
C SERIAL INTERFACE RTC
IDT®
REAL-TIME CLOCK WITH I
2
C SERIAL INTERFACE 18
IDT1337AG REV C 011514
Timing Diagram
Typical Operating Characteristics
Oscillator Frequency vs Vcc
(as measured on one IDT1337C sample)
32768.3
32768.32
32768.34
32768.36
32768.38
32768.4
1.3 2.3 3.3 4.3 5.3
Vcc(V)
Frequency (Hz)
Freq

1337AGDVGI

Mfr. #:
Manufacturer:
IDT
Description:
Real Time Clock RTC I2c Serial IC 1.8 to 5.5V 32kHz
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union