Q6040K7TP

Revised: 07/20/17
Specifications are subject to change without notice.
©2017 Littelfuse, Inc
Teccor
®
brand Thyristors
40 Amp Alternistor (High Commutation) and Standard Triacs
Qxx40xx Series
Figure 3: Normalized DC Holding Current
vs. Junction Temperature
Figure 4: Normalized DC Gate Trigger Voltage for
All Quadrants vs. Junction Temperature
+ 125
0.0
1.0
2.0
3.0
4.0
-40 -15 10 35 60 85 110
Ratio of I
IH
/ I
IH
(T
J
= 25°C)
Junction Temperature - °C
+125
0.0
0.5
1.0
1.5
2.0
-40- 15 10 35 60 85 110
Ratio of V
GT
/ V
GT
(T
J
= 25°C)
Junction Temperature - °C
Note: Alternistors will not operate in QIV
Figure 1: Definition of Quadrants
MT2 POSITIVE
(Positive Half Cycle)
MT2 NEGATIVE
(Negative Half Cycle)
NOTE: Alternistors will not operate in QIV
MT1
MT2
+ I
GT
REF
QII
MT1
I
GT
GATE
MT2
REF
MT1
MT2
REF
MT1
MT2
REF
QI
QIV
QIII
ALL POLARITIES ARE REFERENCED TO MT1
(-)
I
GT
GATE
(+)
I
GT
-
I
GT
GATE
(-)
I
GT
GATE
(+)
+
-
+125
0.0
1.0
2.0
3.0
4.0
-40 -15 10 35 60 85 110
Junction Temperature -- (°C)
Ratio of I
GT
/ I
GT
(T
J
= 25°C)
Figure 2: Normalized DC Gate Trigger Current for
All Quadrants vs. Junction Temperature
Symbol Parameter Value Unit
R
θ(J-C)
Junction to case (AC)
Qxx40KH6
Qxx40K5/7
Qxx40K4
0.97
°C/W
Qxx40JH6
Qxx40J7
0.95
Note: xx = voltage
Thermal Resistances
Revised: 07/20/17
Specifications are subject to change without notice.
©2017 Littelfuse, Inc
Teccor
®
brand Thyristors
40 Amp Alternistor (High Commutation) and Standard Triacs
Qxx40xx Series
110 100 1000
10
Surge Current Duration – Full Cycles
1
Peak Surge (Non-repetitive) On-State Current
(I
TSM
) – Amps
100
1000
Figure 8: Surge Peak On-State Current vs. Number of Cycles
Supply Frequency: 60Hz Sinusoidal
Load: Resistive
RMS On-State [I
T(RMS)
]: Max Rated Value at
Specific Case Temperature
Notes:
1) Gate control may be lost during and
immediately following surge current interval.
2) Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
T
C
= 25ºC
0
10
20
30
40
50
60
70
80
90
0.6 0.8 1.0 1.2 1.4 1.6
Positive or Negative Instantaneous On-State Voltage (v
T
) - Volts
Positive or Negative Instantaneous
On-State Current (i
T
) - AMPS
Figure 7: On-State Current vs. On-State Voltage (Typical)
0
5
10
15
20
25
30
35
40
45
0 4 8 12 16 20 24 28 32 36 40
RMS On-State Current [I
T(RMS)
] - AMPS
Average On-State Power Dissipation
[P
D (AV)
] - Watts
50
60
70
80
90
100
110
120
130
0 5 10 15 20 25 30 35 40 45 50
RMS On-State Current [I
T(RMS)
] - AMPS
Max Allowable Case Temperature
(T
C
) - ºC
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
Figure 6: Maximum Allowable Case Temperature
vs. On-State Current
Revised: 07/20/17
Specifications are subject to change without notice.
©2017 Littelfuse, Inc
Teccor
®
brand Thyristors
40 Amp Alternistor (High Commutation) and Standard Triacs
Qxx40xx Series
Physical Specifications
Environmental Specifications
Test
Specifications and Conditions
AC Blocking
MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours
Temperature Cycling
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell-time
Temperature/
Humidity
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity
High Temp Storage
MIL-STD-750, M-1031,
1008 hours; 150°C
Low-Temp Storage 1008 hours; -40°C
Resistance to
Solder Heat
MIL-STD-750 Method 2031
Solderability ANSI/J-STD-002, category 3, Test A
Lead Bend MIL-STD-750, M-2036 Cond E
Terminal Finish 100% Matte Tin-plated.
Body Material
UL Recognized epoxy meeting
flammability rating V-0.
Lead Material Copper Alloy
Design Considerations
Careful selection of the correct component for the
applications operating parameters and environment will
go a long way toward extending the operating life of the
Thyristor. Good design practice should limit the maximum
continuous current through the main terminals to 75% of
the component rating. Other ways to ensure long life for
a power discrete semiconductor are proper heat sinking
and selection of voltage ratings for worst case conditions.
Overheating, overvoltage (including dv/dt), and surge
currents are the main killers of semiconductors. Correct
mounting, soldering, and forming of the leads also help
protect against component damage.
Reflow Condition Pb – Free assembly
Pre Heat
- Temperature Min (T
s(min)
) 150°C
- Temperature Max (T
s(max)
) 200°C
- Time (min to max) (t
s
) 60 – 180 secs
Average ramp up rate (Liquidus Temp)
(T
L
) to peak
5°C/second max
T
S(max)
to T
L
- Ramp-up Rate 5°C/second max
Reflow
- Temperature (T
L
) (Liquidus) 217°C
- Time (min to max) (t
s
) 60 – 150 seconds
Peak Temperature (T
P
) 260
+0/-5
°C
Time within 5°C of actual peak
Temperature (t
p
)
20 – 40 seconds
Ramp-down Rate 5°C/second max
Time 25°C to peak Temperature (T
P
) 8 minutes Max.
Do not exceed 280°C
Soldering Parameters
Time
Temperature
T
P
T
L
T
S(max)
T
S(min)
25
t
P
t
L
t
S
time to peak temperature
Preheat
P
r
e
h
eat
Ramp-upRamp-up
Ramp-down
R
am
p
-
do

Q6040K7TP

Mfr. #:
Manufacturer:
Littelfuse
Description:
Triacs Altnstr 600V 40A Iso 100-100-100mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union