Obsolete Product(s) - Obsolete Product(s)
Maximum rating STP16CL596
10/24
3.2 Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
DD
Supply voltage 3.0 3.3 3.6 V
V
O
Output voltage 16.0 V
I
O
Output current OUTn 5 90 mA
I
OH
Output current SERIAL-OUT +1 mA
I
OL
Output current SERIAL-OUT -1 mA
V
IH
Input voltage
0.7V
DD
V
DD
+0.3
V
V
IL
Input voltage -0.3
0.3V
DD
V
t
wLAT
LE pulse width
V
DD
= 3.0 to 3.6V
20 ns
t
wCLK
CLK pulse width 20 ns
t
wEN
OE pulse width 400 ns
t
SETUP(D)
Setup time for DATA 20 ns
t
HOLD(D)
Hold time for DATA 15 ns
t
SETUP(L)
Setup time for LATCH 15 ns
f
CLK
Clock frequency
Cascade operation
(1)
1. If the device is connected in cascade, it may not be possible achieve the maximum data transfer. Please
considered the timings carefully.
25 MHz