Technical Data Sheet
RPC-2.40
Open Circuit
Plug
09S12L-000S3
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2 / 3
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt
● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical data
Frequency range DC to 50 GHz
Return loss ≤ 0.15 dB, DC to 4 GHz
≤ 0.20 dB, 4 GHz to 26.5 GHz
≤ 0.25 dB, 26.5 GHz to 50 GHz
Error from nominal phase
1
≤ 2.0°, DC to 4 GHz
≤ 4.0°, 4 GHz to 26.5 GHz
≤ 6.0°, 26.5 GHz to 50 GHz
1
The nominal phase is defined by the Offset Delay, the Offset Loss and the Fringing Capacitance
Mechanical data
Mating cycles ≥ 500
Maximum torque 1.65 Nm
Recommended torque 0.90 Nm
Gauge 0.00 mm to 0.03 mm
General standard definition
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Z
o
/ Impedance / Z
o
50 Ω
Offset Delay 20.0140 ps
Length (electrical) / Offset Length 6.00 mm
Offset Loss 3.20 GΩ/s
Loss 0.0111 dB/
GHz
Fringing Capacitances
2
2
Fringing Capacitances are determined individually for each Open Circuit and are documented in a Calibration Certificate.
Environmental data
Operating temperature range
3
+20 °C to +26 °C
Rated temperature range of use
4
0 °C to +50 °C
Storage temperature range -40 °C to +85 °C
RoHS compliant
3
Temperature range over which these specifications are valid.
4
This range is underneath and above the operating temperature range, within the Open Circuit is fully functional
and could be used without damage.