DATA SHEET • SKY65014-92LF
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200355 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 8, 2006 3
Characteristic Value
RF input power 15 dBm
Supply voltage 5 V
Supply current 120 mA
Power dissipation @ T = 25 °C 600 mW
Operating temperature -40 °C to +85 °C
Storage temperature -65 °C to +125 °C
Absolute Maximum Ratings
Pin Number Pin Name Description
1, 2, 4, 5 GND Equipotential point – Internal circuit com-
mon, which must be connected to the PCB
ground or common via the lowest possible
impedance.
3 Input RF input – RF input with 50 Ω nominal
input impedance. An internally generated
DC voltage is present at this pin, so an
external DC block should be used to
connect this pin to the external circuit.
6 Output RF output – DC supply voltage input and
RF output with 50 Ω nominal output
impedance. The nominal voltage required
at this pin is listed in the Electrical
Specifications Table. Supply current is
determined by an external resistor
connected between the DC power supply
and this pin.
Pin Descriptions
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
SC-88 (6-Lead SC-70)
Application Note.