MPX2102
Sensors
Freescale Semiconductor, Inc. 3
Pressure
Operating Characteristics
Table 1. Operating Characteristics (V
S
= 10 V
DC
, T
A
= 25°C unless otherwise noted, P1 > P2)
Characteristic Symbol Min Typ Max Units
Pressure Range
(1)
Absolute Pressure Range MPX2102A
Differential Pressure Range MPX2102D
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
P
OP
P
OP
20
0
—
—
100
100
kPa
kPa
Supply Voltage
(2)
2. Device is ratiometric within this specified excitation range. Operating the device above the specified excitation range may induce additional
error due to device self-heating.
V
S
— 10 16 V
DC
Supply Current I
O
— 6.0 — mAdc
Full Scale Span
(3)
3. Full Scale Span (V
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum related pressure.
V
FSS
38.5 40 41.5 mV
Offset
(4)
MPX2102D Series
MPX2102A Series
MPXM2102D/G Series
MPXM2102A Series
4. Offset (V
OFF
) is defined as the output voltage at the minimum rated pressure.
V
OFF
V
OFF
-1.0
-2.0
-1.0
-2.0
—
—
—
—
1.0
2.0
1.0
2.0
mV
mV
Sensitivity ΔV/ΔΡ — 0.4 — mV/kPa
Linearity
(5)
MPX2102D Series
MPX2102A Series
MPXM2102D/G Series
MPXM2102A Series
5. Accuracy (error budget) consists of the following:
Linearity: Output deviation from a straight line relationship with pressure, using end point method, over the specified pressure range.
Temperature Hysteresis:Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure with the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure at 25°C.
TcSpan: Output deviation at full rated pressure over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative to 25°C.
—
—
—
—
-0.6
-1.0
-0.6
-1.0
—
—
—
—
0.4
1.0
0.4
1.0
%V
FSS
%V
FSS
Pressure Hysteresis
(5)
(0 to 100 kPa)
— — ±0.1 — %V
FSS
Temperature Hysteresis
(5)
(-40°C to +125°C)
— — ±0.5 — %V
FSS
Temperature Coefficient of Full Scale Span
(5)
TCV
FSS
-2.0 — 2.0 %V
FSS
Temperature Coefficient of Offset
(5)
TCV
OFF
-1.0 — 1.0 mV
Input Impedance Z
IN
1000 — 2500 W
Output Impedance Z
OUT
1400 — 3000 W
Response Time
(6)
(10% to 90%)
6. Response Time is defined as the time from the incremental change in the output to go from 10% to 90% of its final value when subjected to
a specified step change in pressure.
t
R
— 1.0 — ms
Warm-Up Time — — 20 — ms
Offset Stability
(7)
7. Offset stability is the product’s output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
— — ±0.5 — %V
FSS