P O W E R T R A N S F O R M E R
Chassis Mount: Universal
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013
F-91X
Electrical Specifications (@25C)
1. Primary: 115V
1
, 60 Hz
2. Secondary: 0-10V, 20VCT, 40VCT @ 0.3ADC
2
3. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-91X is a chassis mount power transformer that was designed with multiple primaries and
secondaries to give the user maximum flexibility. The F-91X is intended for use with full wave center tap
or bridge rectifiers, but may be used with voltage doubler circuits at one half of the rated current.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B (130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between primary and secondary
windings as well as between the primary / secondary windings and the core.
Dimensions: Units: inches
Weight: 1.50 lbs
Connections:
Primary – 22AWG, UL 1015, 7.0 “± 1”, strip & tin 0.250” ± 0.062”
Secondary – 22AWG, UL 1015, 7.0 “± 1”, strip & tin 0.250” ± 0.062”
Schematic:
BLK/WHT
BLK/GRN
BLK/YEL
BLK
BLK/RED
RED
BLUE
YEL
GRN
PRIMARY
COM
10 V
20 V
40 V
COMMON
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
Tapped primary to produce lower output voltages.
2
DC amp rating with a full wave bridge rectifier.
BLK/RED
BLK
BLK/YEL
BLK/GRN
BLK/WHT
RED
BLUE
YEL
GRN
REF
REF
REF
+/-.030
.187 DIA
2 PLACES
F-91X
2.0
3.125
3.687
2.281